PET Series | Stainless Steel Pressure Tanks
SAFETY VALVE
To prevent exceeding the maximum operating pressure (7 bar)
inside the tank, the lid is provided with a safety valve. If the
calibration pressure is exceeded, the valve opens up releasing
the exceeding air.
WARNING
IT IS FORBIDDEN TO USE:
- HALOGENATED HYDROCARBON SOLVENTS, SUCH AS
TRICHLOROETHANE, METHYLENE CHLORIDE OR THE LIKE;
- HIGHLY TOXIC PRODUCTS SUCH AS PETROL, KEROSENE OR
COMBUSTIBLE GASES;
- HERBICIDES OR PESTICIDES;
- RADIOACTIVE FLUIDS
3. INSTALLATION
3.1 INSPECTION OF PURCHASED PRODUCT
Before using the tank make sure it has not been damaged
during transport or storage. Moreover, make sure all the
components included in the standard supply are inside the
packaging.
3.2 INSTALLATION
FOLLOW THE INSTRUCTIONS BELOW:
1. Place the tank on the ground, on a flat surface.
2. Firmly fix the terminal of the ground cable as shown in
Fig.2.
WARNING
REFER TO THE LOCAL CODE FOR DETAILED
INSTRUCTIONS FOR GROUND CONNECTION RELATIVE
TO THE WORKING AREA AND TO THE SYSTEM USED.
Fig. 1
3. Connect the fluid pipe by means of a 3/8"M outlet fitting (D).
4. Connect the air supply pipe through the G 1/4"M inlet
fitting (L).
L
D
Fig. 2
ø 4mm
4. USE
LIMITS AND CONDITIONS OF USE
Any modification to the constructive shape or to the assembling
position is allowed only after asking for ANEST IWATA technical
service authorization.
4.1 OPERATION
WARNING
BEFORE CARRYING OUT ANY OPERATION, RELEASE
THE PRESSURE ACCORDING TO THE INSTRUCTIONS
PROVIDED IN PARAGRAPH 4.2.
PAINT PREPARATION
Prepare the paint according to the instructions provided by the
manufacturer.
Filter the paint to eliminate the bigger particles that might clog the
gun or obstruct the fluid passages.
TANK FILLING
Perform the pressure release procedure described in paragraph 4.2.
Unscrew the clamps (O), remove the tank lid and pour the paint in
the tank.
Place the lid and tighten the clamps (O) manually, in cross order.
ATTENTION:
NEVER EXCEED THE MAXIMUM FILLING LEVEL.
STARTING THE TANK UP
Close the exhaust valve (N) and connect the supply air hose to the
joint (L).
Open the air inlet ball valve (I).
Adjust the air regulator of the tank (M) to the pressure required,
shown on the pressure gauge (P).
Set the rotation speed of the agitator by means of the regulator (H).
Open the fluid outlet ball valve (E).
WARNING
OVERPRESSURE IN THE PRESSURE TANK OR IN ITS
ACCESSORIES CAN BREAK PARTS OF THE SYSTEM.
4.2 PRESSURE RELEASE PROCEDURE
The Tank remains under pressure until the pressure
is released manually.
WARNING: Follow the instructions to release pressure
from pressure tank:
BEFORE INSPECTING OR OPERATING THE SYSTEM.
AT THE END OF PAINTING OPERATIONS.
1. Interrupt the air supply by closing the air inlet ball valve (I).
2. Disconnect the air inlet hose.
3. Close air regulator (M).
4. Open the exhaust valve (N).
5. Wait until no more air passes
through the exhaust valve (N).
6. Unscrew the clamps (O) and
remove the lid.
7. Leave the exhaust valve (N)
open, until the lid is put
back in place.
EN
I
M
N
5