Maintenance
To avoid any injuries, please switch off the unit and disconnect the power plug before beginning the maintenance
or cleaning.
Cleaning
•
Please disconnect the power plug.
•
Please clean the unit with a moistened cloth and then wipe it off with a dry cloth. Please do not use
chemical solvents (such as petrol or alcohol). The surface as well as the entire housing could be damaged.
•
Please never clean the appliance with water.
Air filter
•
Please clean the air filter regularly. When the air filter has become blocked with dust, its
efficiency will be reduced.
•
Please wash the air filter by immersing it in warm water (approx. 40 °C) using a neutral
cleaning agent, rinse it under running water and subsequently dry it with a soft cloth.
•
Please do not operate the unit without an air filter.
Storage
•
Please disconnect the power plug and empty the water tank.
•
Please allow the appliance to operate in fan mode for approx. 2 hours so the interior assembly can dry.
•
Please switch off the unit and disconnect the power plug.
•
Please clean and dry the air filter, then reinstall it in the unit.
•
Please disconnect the outlet hose from the unit and store it safely.
•
Please place the unit in a box and store it in a dry place.
•
Remove the batteries from the remote control and store these safely.
Faults
Do not try to install/disassemble/repair the unit yourself. Incorrectly performed work can cause electric shock,
water leakage, fire and similar.
Fault
1. The unit will not
start
2. The unit does not
cool correctly.
3. The unit switches
off after a short period
of time
4. Noise
5. Compressor is not
running
6. Unpleasant smell
during operation
7. The
symbol is
shown on the display
Reason
No power
– Display lights up
Internal safety function was
activated
Windows and doors are open, other
heat sources are present in the
room (causing a fluctuation in
temperature)
Direct sunlight
Outlet
hose not connected or
blocked
Air inlet is blocked
Outlet hose is kinked
Air outlet is blocked
The unit has not been placed on a
level surface
Thermal protection has been
activated.
Air filter is dirty
The internal frost protection
function was activated to prevent
the formation of ice in the inside of
the unit.
Solution
Please provide the unit with power and turn it on.
Please empty the water tank.
Please switch the unit off, wait 30 minutes and switch
it on again. Should the problem persist, please
contact your point of sale.
Please close all windows and doors and remove the
heat source.
Please position the unit in the shade or close the
curtains.
Please connect the outlet hose or clean it, if
necessary.
Please clean the blocked point
Please position the outlet hose straight and keep it as
short as possible to increase the unit's efficiency.
Please check the air outlet and clean it, if necessary.
Position the unit on a hard, level surface (this reduces
the noise)
Please switch the unit off and restart it after 3 minutes.
Please clean the air filter as described in the chapter
"Maintenance/cleaning".
Please wait. The unit will start automatically as soon
as the process has been completed.
21