Technical specifications
Voltage
Output
Temperature
Display type
Airflow regulation
Airflow rate
Air pressure
Delivery nozzle
Emission sound pressure level
Total vibration value
Motor life
Heating element life
Power cord
Weight (without power cord)
Dimensions
Operation
Turn the tool ON at the
ON/OFF switch.
Preset the temperature
you require
(25–600°C) at the temperature regulator.
The temperature level as well as the letter
"A" to show the setting mode are indicated
on the LED segment display. Once the
temperature has been preset, the tool
automatically starts to show the actual
temperature after approx. 3 seconds.
The selected and actual temperatures are
displayed in 10°C increments.
The airflow rate can be continuously varied
at the airflow regulator
.
These regulations reflect the latest
standards on mains pollution
(EN 61000-3-3 Flicker standard,
EN 61000-3-2 Harmonics standard).
230–240 V / 50 Hz
3400 W
25–600°C, infinitely variable
LED segment display
infinitely variable
max. 800 L/min.
3000 Pa
Ø 50 mm
≤ 70 dB (A)
≤ 2,5 m/s² / K = 0,08 m/s²
approx. 20000 hrs.
approx. 500–800 hrs.
H07 RN-F 2 × 1.5
Length: 2.5 m
1190 g
350 x 122 x 67 mm (at the knock guard
The tool has intelligent temperature and
airflow control. This always gives priority to
the temperature setting (see diagram).
Example: to reach the maximum tempera-
ture of 600°C while setting the motor speed
to max. air delivery, the electronic system
automatically reduces the airflow rate until
600°C is are reached. Accordingly, the air-
flow rate is increased again as soon as the
temperature is lowered.
- 16 -
Intelligent motor and temperature control
Motor speed
(rpm)
Delivery temperature
)
Changing the heating element
The plug-in heating ele-
ment in the HG 5000 E
can be changed in a
matter of seconds. Every
heating element contains
Intelligent motor and temperature control
a chip with your specific
data. On fitting a new
heating element, its
parameters are imported
by the control electronics.
- 17 -
Dyn. pressure
(hPa)
1. Important! Disconnect
tool from power supply.
2. Undo four screws at
the end of the delivery
nozzle.
3. Detach heating element
and replace it with a
new one.
4. Firmly screw delivery
nozzle back on again.