with only one output, while the same output can be associated with multiple keys.
PROCEDURE 2 - Mode 2 memorisation (and extended Mode 2)
01.
In the control unit manual: choose the command to be memo-
rised and remember its "identification number".
02.
On the receiver: press and release key A for a number of times
matching the number that identifies the command chosen at
step 01: LED B will flash the same number of times.
03.
On the transmitter with the key to be memorised:
• (within 10 seconds) on the transmitter: hold down the key to be
memorised and release it once LED B (on the receiver) emits the
1
of 3 green flashes (=memorisation completed correctly). (*2)
st
(*2) Note - If there are other keys to be memorised (belonging to other transmitters) with the same com-
mand, repeat step 03 within the next 10 seconds for each further key to be memorised (the procedure
terminates once this time elapses).
3.3 - Memorising a new transmitter "near the receiver"
This procedure allows for memorising a new transmitter by means of a second functioning transmitter, already
memorised in the same control unit. This enables the new transmitter to receive the same settings as the
transmitter already memorised. The procedure does not entail any direct action on key A of the receiver, only
the presence of the transmitter within the receiver's reception range.
• The memorisation "near the receiver" can be prevented by blocking the receiver's function through Procedure
6 (Paragraph 3.7). Alternatively, the receiver can also be blocked with the O-Box programmer.
x No. ....
=
...