SPECIFICATIONS
Gas category: Direct Pressure – Butane-Propane mixture. Canister
must conform to the EN417 or AS2278 standard. This appliance
is only intended for use with 100g/230g/450g Jetboil Jetpower
Isobutane/Propane Fuel Canisters (sold separately). It may be
hazardous to attempt to fit other types of gas containers.
Jet Size: 0.31mm Gas Consumption: 120 g/hr [2 kW] (EU) || 6,000
BTU/hr (CA) Jet Size (AU): 0.28mm Gas Consumption: 6 MJ/hr
LEAK CHECK
PROCEDURE
1. Perform leak checks outside, in a well-ventilated area.
2. Connect fuel canister (3.1) to valve (3.2) by threading in the
orientation shown in Fig 4.
3. Put soapy water on the gas connection between fuel canister and
the valve. Formation of bubbles indicate a gas leakage.
Do not check for leaks using a flame.
WARNING
If a leak is detected, do not attempt ignition. Remove fuel
WARNING
canister immediately and contact Customer Service.
4. If no leak is found, detach fuel canister. Leak check is complete.
4