Checking Leds - Allied Telesyn AT-8900 Serie Guía De Instalación Y Seguridad

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
AT-8900, AT-9900, AT-9900s Series Switches
5.
Change the password.
Change the password as soon as possible because a manager account with
the default password is a serious security risk. Remember the new
password because there is no way to retrieve it if you forget it.
To change the account password, use the set password command.
6.
Display help for commands as necessary.
To display a list of help topics, use the help command.
To display help on a specific topic, use the help <topic> command.
Alternatively, display a list of valid options by typing a question mark at the
end of a partial command.

Checking LEDs

Table 1 describes how LEDs on the switch report faults and operational
activities.
Table 2 on page 14
modules report faults and operational activities.
LEDs for Ethernet ports and Small Form Factor Pluggable (SFP) ports are
described in the Hardware Reference.
Table 1: System LEDs
LED
PSU 1
12
describes how LEDs on power supply units and fan-only
State
Description
Green
PSU 1 is installed and supplying power to the switch.
The voltage output is within specification.
Red
PSU 1 is installed in the switch and has exceeded its
recommended temperature threshold of 75º C
(167º F), or the fan has failed.
A FOM is installed in the switch and has failed.
The bay is empty.
Off
A FOM is installed and operating at an acceptable
speed.
For AT-9924T and AT-9924SP models, this LED is
always off because a FOM is not required.

Publicidad

Tabla de contenido
loading

Tabla de contenido