PS 400 5.959-067
ENGLISH
Starting the charging process:
Connect the charging plug of the charger with the charging
socket on the unit.
Connect charger to the mains, charging process begins (charging
time approx. 14 hours).
Ending the charging process:
First draw out the mains plug and then the charging plug.
Check the electrolytes in the charging window every 40 hours or
monthly.
Checking the electrolytes of the battery 12 V, 50 Ah
(5)
Take out the debris container.
By means of the marking check the state of the electrolytes at the
viewing window, fill up with distilled water if necessary. For this
purpose take off the cover and clean the battery with a dry cloth.
You must follow the instructions!
Notes on the battery
The installed battery is maintenance-low, i.e. the water con-
sumption is minimised. Despite this the level of liquid must be
checked regularly (see Maintenance plan).
The battery is precharged dry at the works, and the appropriate
quantity of acid is added. Fill the battery according to the
accompanying instructions and carefully observe the safety notes.
You are recommended to fully charge the battery after filling it.
Please charge the battery after each use of the unit.
7