NOTE
•
Operating hours counter (item 3)
The operating hours counter counts the hours of use of the product. It
enables you to collect information about the operating life of the
product, but also to monitor the service life of the filters used. This way
the replacement filters can be ordered in time to change them.
•
Signal horn (item 4)
Reliable capture of welding fumes is only possible with sufficient
extraction capacity. As the dust accumulation in the filter increases, its
flow resistance increases and the extraction capacity decreases.
As soon as it drops below a minimum value, the signal horn sounds.
A filter change is now required.
The same happens if the damper flap in the extraction hood is closed
too far and the extraction capacity is reduced too much.
This can be remedied by opening the throttle valve.
6.3 Commissioning
WARNING
Danger due to faulty product condition.
The product must be fully installed before commissioning begins. All
doors must be closed and the necessary connections must have been
made.
1. Connect the power supply connection cable of the product to the on-
site power supply.
2. Switch the product on using the pushbutton marked "0" and "I".
3. The fan starts and the green indicator lamp on the device switch
indicates error-free operation.
If there is a fault, please refer to the "Troubleshooting" chapter.
1502764-01
- 60 -
EN