Close the cover of the low tension box (21).
The new voltage connection must be written at the rating plate.
16 BLADE TURNS ON THE OPPOSITE DIRECTION, SOLUTION
1.- Unplug the machine.
2.- Open the low tension box (21).
3.- The network cables (13) colour blue, black and brown which go on connector at box (21) to numbers 1,
3 and 5 must be interchanged two from the three. See the wiring diagram.
4.- Place the cover of the box (21).
17 FUSE CHANGE
1.-Unplug the machine.
2.-Open the 24V plate box (21).
3.- Replace the fuse with a new one: For the F2 fuse the reference is 5 x 20, 250 V, 2 amperes and for the
F3 fuse the reference is 5 x 20, 250 V , 0'5 amperes.
4.- Place the door cap again.
WIRING DIAGRAM II, CENTRAL CODIFIED SYSTEM.
Wiring diagram II 230 V. Central codified system for one sensor.
CONDENSER
brown
MOTOR WITH
THERMIC
50 y 60 Hz.
PROTECTION
24 V.
LAMP.
1,2 W.
ON
OFF
CODIFIED
MAGNET
blue
green-yelow
white
230 V.
black
~
black (1)
X1
X2
4
black (2)
black (3)
3
2
1
black (4)
CODIFIED SENSOR
PLUG PROTECTION
OF THE CLIENT
green-yelow
green-yelow
CONTACTOR
2
4
6
black (3)
14
black (1)
A2
CONNECTOR
black (2)
white
white
brown
yelow
green
white
22
FUSE F1
FUSE F3
brown
1
0,5 A.
3
blue
5
0,5 A.
13
FUSE F3
A1
black
black (4)
SWITCH-BOARD
1
5
2
6
A1
A2
3
7
13
14
4
8
TRANSFORMER
2 A.
FUSE F2