iCLASS
R10, R15, R30, R40, and RK40
2
Wiring
CP1
CP2
P6
Terminal Reader with Hi-O Module
P6 Group Select Option
Group 1
Shorted
(Default)
(Outside - Jumper Installed)
Group 2 Open
(Inside - No Jumper)
PIN
GND
+VSPLY
CAN_H
CAN_L
Core OC_OUT /
SABOTAGE_OUT
HSI_SABOTAGE_IN
4
INSTALLATION GUIDE
7
6
5
4
3
2
CP1
1
2
3
4
5
6
CP2
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
Note: P6 connector found on the underside of module.
CAUTION: Tamper functionality is dependent upon correctly installing
the jumper wire between CP2-5 and CP2-7. Ensure correct installation
and test the tamper switch after installation.
COLOR
DESCRIPTION
Ground (RTN) - External supply common return. Also a con-
Black
nection point for CAN_GND and optional CAN_SHIELD.
+VDC (5-16 VDC) External power supply input.
Red
WARNING: Do not connect Hi-O 24 VDC Power Supply.
White
Differential CAN bus 'high' signal I/O pin
Brown
Differential CAN bus 'low' signal I/O pin
(Alt Green)
OC and Tamper switch output from core module (open col-
lector). Requires a jumper to HSI_SABOTAGE_IN
Tamper switch detects input to HSI module. Pulled up to
+5VDC. Allows sabotage detection and messaging over
Hi-O network. Requires a jumper to OC_OUT.
C
ableado
C
âblage
f
iação
V
erdrahtung
ТАБЛИЦА рАсКЛЮЧЕнИЯ ПрОВОДОВ
1
Terminal
Block Wiring
7
Keypad Terminal Reader
©2009 HID Global Corporation. All rights reserved.
3170-901 B.0
C
ablaggio
配線
布线
배선
CP1 CP2
P6
with Hi-O Module
PCB
LOCATION
CP1-3
CP1-5
CP1-4
CP2-1
CP2-2
CP2-5
CP2-7