7.- Other peripherals (AZX6CCP, AZX6WEBSCLOUD [C/R], ...)
You can find the instructions on how to connect and configure other peripherals on their data sheets.
8.- Powering the system
Use the power input to power at 110 / 230 Vac
control elements that require it. Use the appropriate cable (3x1.5 mm²). For added
security, secure the wires using the turret.
Important: According to the current local and national regulations, it is mandatory to add a switch
(or other element to disconnect the system) to the external supply wiring so that a constant separation
between poles is guaranteed. The system will restart automatically if the supply is eventually turned
off. Use an independent circuit from the controlled system for the power supply.
Remember: Once all the connections are made, make sure you replace the cover properly.
Reset the system
If you want to return to factory values, press and hold SW1
LEDS to go back to their normal state before starting with the initial configuration process.
Zone reset
If needed, to reset a zone follow the steps shown in the section Advanced settings, Zone Settings for Blueface
and Think thermostats and the section Lite thermostat Reset if using Lite thermostats.
Changing batteries
In order to replace the battery, please remove the thermostat from its support
and then replace it (CR2450).
Important: We recommend the use of top-brand batteries. Using low-quality
batteries may reduce the duration of use.
Remember to deposit the old battery into an appropriate recycling point.
Note: Do not forget to remove the security system before taking away the thermostat from the wall.
the main control board and any others
until LED D19 stops flashing. Wait for the
ES
EN
FR
IT
PT
DE
31