PRODUCTION SETTINGS
Important: The Production control board settings are only available in the master Blueface thermostat of the system nº1.
•
Operation logic. It allows to configure the operation logic for the control relays of the production control board:
-
Aerothermal unit (Default preset)
-
2 pipes
-
4 pipes
-
RadianT (Recommended for RadianT365 systems)
•
Activation delay. It allows to set a delay time in the power on of the production unit, configurable in minutes, from 0
to 10. (Default preset to 3 minuts).
•
LWT temperatures. (Only available in installations with gateway AZX6GAW[XXX] provided that the aerothermal unit
is not configured to work automatically, allowing the imposition of working temperatures). It allows to set the LWT
temperaturas for the heatting and cooling modes of the aerothermal unit. Selectable values depends on each
particular aerothermal unit. Default presets are:
-
Air in cooling mode: 10 ˚C
-
Radiant in cooling mode: 18 ˚C
-
Air in heating mode: 50 ˚C
-
Radiant in heating mode: 35 ˚C
•
DHW function. (Only available in installations with AZX6GAW XXX control gateways) It allows to turn on/off the Domestic
Heat Water (DHW) function in the systems connected to the CCP. Activated by default.
•
Cooling mixing valve (only available in installations with aerothermal gateway). It allows you to configure the
operation of your installation depending on whether or not you have a cooling mixing valve.
Select Manual in the case of having cooling mixing valves in your installation, in which case they must be set at 18°C.
If the installation does not have a cooling mixing valve, select Auto so that the installation works automatically with
the temperature read by the system. By default it is set as Manual.
INCIDENCES
If an error message is shown, you can check both the Installation Manual and the Self-diagnosis section. Please visit Myzone