4.
CONNECTIONS
J1
DESCRIPTION OF TERMINAL-BOARDS
Terminal
Description
Device with NO contact.
1
OPEN
(chap. FUNCTION LOGICS)
Device with NC contact.
2
FSW
shuts down automated system
Device with NC contact.
3
STOP
shuts down automated system
4
- 24Vdc
Power supply to accessories
5
+ 24Vdc
Negative controlled for photocells
FAIL
6
SAFE
(see fail safe function)
7
C
Motor common contact
8
OP
Motor Opening stage
9
CL
Motor Closure stage
Flashing lamp output
10 11
LAMP
230Vac max 60W
5. LOGIC AND FUNCTIONS PROGRAMMING
The function logic and the relevant functions can be selected by
confi guring the DS1 microswitches group as per table below.
ON
SW1
ACTIVE 5 sec
INACTIVE
SW2
Logic A
Logic EP
SW3
Reopens
Reopens when
immediately
disengaged
SW4
FSW control
FSW control
active
inactive
Pause time adjustment
Pause time can be adjusted with trimmer TR1, varying the
pause from 0 to 60 secs. Turn the trimmer clockwise to increase
time.
7. AUTOMATED SYSTEM TEST
When you have fi nished programming, check if the system is
operating correctly. In particular, check if the safety devices are
operating correctly.
FAAC
200MPS
OP FSW STOP
-
+ -TXFSW
1
2
3
4
5
6
Other safety
device
RX CL1
TX CL1
1
2
1
3
2
4
5
Device connected
ON
1
2
3
OFF
FLASHING LAMP
PRE-FLASHING
FUNCTION
LOGICS
SAFETY DEVICES
TRIPPED
FAIL SAFE
COM
OP
CL
LAMP
7
8
9
10
11
M
DESCRIPTION OF INPUTS
1. OPEN command.
Any pulse generator with NO contact which opens the gate
when activated. In EP logic, it also commands closure.
2. FSW safety devices and/or other safety devices.
All devices, such as photocells or sensitive edges etc with
an NC contact - if they are activated, they generate an
opening or shut-down of the automated system according to
programming.
3. STOP command.
Any NC pulse generator, which commands instant shut down of
the automated system until a new OPEN command is given.
4. FAIL SAFE.
When using this terminal for connecting the negative wire
to power the transmitters and photocells, you can use the
FAILSAFE function. If this function is enabled, the unit
verifi es the operation of the photocells before every closing
cycle.
If you do not intend connecting any device to
terminals 2 and 3, you must jumper connect them
to terminal 4.
6. FUNCTION LOGICS
The automatic or semi-automatic function logic can be selected
with the SW2 microswitch, as shown in fi g. 3.
A AUTOMATIC Logic
Status
4
Opens and closes
Closed
after pause time
Opening
Recharges
Open
pause time
Closure
Blocked
EP SEMI-AUTOMATIC Logic
Status
Closed
Opening
Open
Closure
Blocked
Opens/closes
8. MAINTENANCE
The 200MPS control board does not require any special periodic
controls. In the event of faults, it is important to control the fuses
and the status LEDs.
2
N
L
J4
12
13
230Vac
230V
Max60W
Fig. 2
Open
Stop
(pulse)
Disables
Open and Close
/
Blocks
Blocks
Opens
Blocks
Disables
Opens
Open and Close
Open
Stop
(pulse)
Opens
/
/
Blocks
CLOSES
Blocks
Opens
Blocks
/
Safe(FSW)
/
/
Recharges
pause time
Opens
Inhibits
closure
Safe(FSW)
/
/
Blocks
Opens
/