As soon as you receive the product, check that it is in perfect
condition and if not, immediately notify the forwarding agent.
- All measurements are provided in centimetres
- The reference diagrams are not to scale
Info
Sasha Mi supports the following installation types (refer also to the
relevant instructions):
WALL MOUNTED
ref. "a" - with the panel P1 (provided) and the covering panels P
(optional).
The panel P1 closes up the space by the equipment zone ,
whilst the panels P are installed behind the front frame (W).
ref. "b/c" - without covering panels P.
The cladding system (plasterboard, etc.) can be installed as in-
dicated, it must, however, lean against the front frame (W);
the size of the area is based on the measurements.
It is also possible to install the Sasha appliance away from a
corner of the room (or between corners, ref. "c ") and there-
fore close up the remaining space, so that once the installation
process is complete, the cladding will be positioned behind
the front frame (W) (part F2).
CORNER
ref. "d" - with the panel P1 (provided).
Should you wish to install a panel to close off the appli-
ance area between the covering frame and the ceiling,
you must ensure adequate ventilation, as instructed;
in addition, you must ensure that the entire panel is
completely removable for inspection and/or subse-
quent maintenance operations of the hydraulic com-
ponents present on the upper limit of the appliance.
Install the appliance to walls without skirting boards
and/or projections.
Any installation types/methods which differ from
those specified must be assessed on an individual
basis and must comply, without fail, to the provisions
specified above.
The installation area must comply with the following character-
istics:
- Optimal room temperature: approximately 22-25 °C
- Room height: min 250 cm
- Walls: straight and level where possible.
- Flooring: tiled or laid; in any case, it must be waterproof;
this includes the front area of the appliance.
With the sauna module, the flooring must not be plastic
or carpeted.
NOTE: we recommend placing a collection pit at the centre of the
installation area (Pr) designed to deal with water leakages in the
event of faults or malfunctioning; with this aim in mind, the floor
must be sloping (see
The supports (feet) of the appliance frame, present across the
entire surface, must always rest completely against the floor, and
subsequently conform to dimensions.
Pr
Pr
Drainage system
- It is best to lay in the drainage as indicated in position 1.
In addition, it is necessary to route drainage pipe fittings to the
floor, as indicated, whilst bearing in mind the positioning of the
frame supports (feet).
7