LaserLiner SuperCross-Laser Compact Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
Preparing the calibration check
5
It is possible for you to check the calibration of the laser. To do this,
position the device midway between 2 walls, which must be at
least 5 metres apart. Do this by turning the unit on, thus releasing
the transport restraint (cross laser on). See Section „Horizontal and
vertical levelling" about this.
1. Mark point A1 on the wall.
2. Turn the device through 180° and mark point A2. You now have
a horizontal reference between points A1 and A2.
1.
A1
2.
Performing the calibration check
6
3. Position the device as near as possible to the wall at the height
of point A1.
4. Turn the device through 180° and mark point A3. The difference
between points A2 and A3 is the tolerance.
3.
A1
4.
When A2 and A3 are more than 5 mm / 10 m apart, an
!
adjustment is necessary. Contact your authorised dealer
or else the UMAREX-LASERLINER Service Department.
Checking the vertical line: Position the device about 5 m from a
wall. Fix a plumb bob with a line of 2.5 m length on the wall, making
sure that the bob can swing freely. Switch on the device and align the
vertical laser to the plumb line. The precision is within the specified
tolerance if the deviation between the laser line and the plumb line
is not greater than ± 1.5 mm.
Checking the horizontal line:
Position the device about 5 m from a wall
and switch on the cross laser. Mark point B
on the wall. Turn the laser cross approx.
2.5 m to the right and mark point C.
Check whether the horizontal line from point C is level with point B
to within ± 2 mm. Repeat the process by turning the laser to the left.
SuperCross-Laser Compact
A2
A2
A2
A3
A2
A3
B
2,5 m
C
09
GB

Publicidad

Tabla de contenido
loading

Tabla de contenido