Ega Master 57542 Manual De Instrucciones página 80

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Then, it is necessary to prepare the wrench's calibration data and the tester. This process
consists of 3 points:
1. Calculate the wrench's 20%, 60% and 100% maximum torsion range and
2. Do a testing to obtain the tester's values.
3. In the testing with a determined weight, get the wrench's value and write it down. Please see
the next image as example:
Example of test data:
% OF MAXIMUM TORQUE
20%
60%
100%
20%, 60% and 100% of the maximum torque range are calculated for the torque wrench and
the test is carried out to obtain the values of the tester.
It is necessary to connect the dynamometric wrench in off mode to the computer. Then,
turn it on and set it in SEND mode.
- Press U/S for some seconds (till hearing a sound).
- Press U/S
- Press U/S
- Press C
- Press U/S
- Press ^
80
TORQUE WRENCH
48.6
91.8
135
TESTER
48
91
135