Uline H-7593 Manual De Operación página 3

Ocultar thumbs Ver también para H-7593:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

REPLACING THE KNIFE
To replace a blunt, dull or broken knife:
1.
Lift sealing bar and press down on head of knife assembly.
(See Figure 6)
2.
Pull knife out of its housing with pliers. (See Figure 6A)
3.
Insert new knife with pliers.
OPERATING ISSUE
LED lamp does not illuminate. Machine does not seal.
LED lamp illuminates yellow but does not change to
red when handle is closed. Machine does not seal.
LED lamp illuminates normally, but machine does
not seal.
Sealing is not acceptable.
Loose handle.
Sealing wire heats up immediately when machine is
plugged in.
TYPE
H-7593
H-7594
TYPE OF
TRANSFORMER
H-7593
H-7594
PAGE 3 OF 12
MAINTENANCE CONTINUED
TROUBLESHOOTING
RECOMMENDATIONS
Ensure the machine is connected to an electrical outlet.
Is the outlet "live?"
Check if the control panel is damaged.
Ensure that sufficient force is used to press handle down.
(Do not press the handle sideways.)
Is the front cap on the handle? Is the magnet inside it?
Check if the control panel is damaged.
Unplug from power immediately. Ensure sealing wire, PTFE tapes and
transformer are intact.
Change sealing time with regulator button. (Sealing time increases
proportionally with thickness of film.)
After sealing, allow 1-2 seconds to cool. (Cooling time increases
proportionally with sealing time.)
Tighten hinge bolts.
Check if the control panel is damaged.
Immediately unplug from electrical power and call Uline at 1-800-295-5510.
TECHNICAL INFORMATION
SEALER
SEALING
MAXIMUM
SIZE
LENGTH
FILM WIDTH
16"
16.6"
24"
24.6"
PRIMARY/SECONDARY
NOMINAL VOLTAGE
110/17,6 V
Figure 6
CUTTING
LENGTH
15.75"
15.75"
24.5 x 25.5 x 43.5"
23.62"
23.62"
32.3 x 25.5 x 43.5"
NOMINAL
NOMINAL
ELECTRIC POWER
CURRENT
240 w
2,2 a
A
MACHINE
NET
DIMENSIONS
WEIGHT
62 lbs.
73 lbs.
USED FUSES
6 a
0421 IH-7593

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

H-7594

Tabla de contenido