3.4.4.5. When vacuuming up liquids, ensure the
vacuum is positioned between a 40 and 90 degree
angle.
NEVER ALLOW LIQUIDS TO COME INTO CONTACT
WITH THE MOTOR!!
3.4.4.6. When finished, empty the dust container of all
liquid and dry before storage. Storing it with risidual
liquid or damp can result in poor suction and can
increase the chance of electrical shock when docking
the vacuum on the docking station.
NOTE: DO NOT allow the liquid in the dust container
to exceed the MAX marked on the side.
4. Cleaning and maintenance:

4.1. Removing the dust container:

4.1.1. Press the dust container release button on the
top of the handle and slide the dust container away
from the motor section.
4.1.2. To re-fit the dust container, slide the container
back onto the motor section until it clips in place.
4.2. Cleaning the dust container and filter:
4.2.1. Remove the dust container.
4.2.2. Remove the filter by sliding the filter holder out
of the dust container.
4.2.3. Clean the dust filter and the inside of the dust
container.
4.2.4. Re-fit the filter inside the dust container (ensure
the filter is pushed fully up to the plastic stops inside
the container) and re-fit the dust container to the
vacuum.
The filter is washable but after time it will need to be
replaced. Replacement filters are available to purchase.
Please see details in the rear of this manual.
31350_IM.indd 5
5. Care and maintenance:
5.1. IMPORTANT: Always unplug the appliance from
the power socket during cleaning and maintenance.
Never use sharp instruments or abrasive substances,
soap, household cleaner, detergent or wax polish for
cleaning. Clean the external surfaces with a damp soft
cloth only.
6. Anomalies and repair
6.1. Take the appliance to an authorised support centre
if product is damaged or other problems arise.
6.2. If the connection to the mains has been damaged,
it must be replaced and you should proceed as you
would in the case of damage
7. Technical data:
AC: 220-240V ~ 25W 50/60Hz
DC: 4.8V

8. Troubleshooting

Problem
Reason(s)
No Power
-Battery drained
Low or no suction
-Battery is
power
drained
-Dust container
is full
-Filter is clogged
Dust leaking from
-Dust container
the unit
is full
-Dust container
is not fitted to the
motor section
correctly
Solution(s)
-Charge the bat-
tery fully
-Charge the bat-
tery fully
-Empty the
container
-Clean the filter
-Empty the
container
-Re-fit the dust
container