Troubleshooting
The Laser Does Not Turn On
• Make sure AA batteries (when used) are installed correctly
according to (+) and (–) on the inside of the battery door.
• Make sure the batteries or rechargeable pack are in proper
working condition. If in doubt, try installing new batteries.
• Make sure that the battery contacts are clean and free of
rust or corrosion. Be sure to keep the laser level dry and use
only new, high-quality, name brand batteries to reduce the
chance of battery leakage.
• If the laser unit is heated above 50 ˚C (120 ˚F), the unit will
not turn on. If the laser has been stored in extremely hot
temperatures, allow it to cool. The laser level will not be
damaged by pressing the on/off button before cooling to its
proper operating temperature.
The Laser Beams Flash
The DCE088R and DCE088G have been designed to self-
level up to an average of 4° in all directions when positioned
3
as shown in
. If the laser is tilted so much that internal
mechanism cannot level itself, the laser beam will flash
indicating that the tilt range has been exceeded. The flashing
beams created by the laser are not level or plumb and
should not be used for determining or marking level or
plumb. Try repositioning the laser on a more level surface.
The Laser Beams Will Not Stop Moving
The DCE088R and DCE088G are precision instruments.
Therefore, if the laser is not positioned on a stable (and
motionless) surface, the laser will continue to try to find level. If
the beam will not stop moving, try placing the laser on a more
stable surface. Also, try to make sure that the surface is
relatively flat, so that the laser is stable.
The Battery Meter LED's Flash
When all 4 LED's continuously flash on the Battery Meter this
indicates that the unit has not been fully powered off using the
Pendulum Lock switch
B
. The Pendulum Lock switch should
always be placed in the LOCKED/OFF position when the laser
is not in use.

Service and Repairs

Note: Disassembling the laser level(s) will void all
warranties on the product.
To assure product SAFETY and RELIABILITY, repairs,
maintenance and adjustment should be performed by
authorized service centers. Service or maintenance performed
by unqualified personnel may result in a risk of injury. To locate
your nearest DeWALT service center go to
http://www.dewalt.com on the Internet.