1.1.2 Description of the menus
ICON
FUNCTION
Power
Stove output setting
Setting of the air fan speed.
Fan
Displays the
temperature.
Temperature
*con g.1:
Fuel
Not used
Enables or disables the timer. When enabled, the icon
Timer
(not ashing)
ICON
FUNCTION
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
Setup
[9]
[10]
[11]
[12]
[13]
[14]
[30]
[31]
[33]
[34]
[40]
Submenus
and
[30]
[40]
DESCRIPTION
probe*
temperature reading and is used to set the desired
water
probe; con g.2: room probe; con g. 3-4: external/tank probe.
SUBMENU
Assigns the programs (max 3) to the different days of the week
Weekly timer
Programs
Program setting menu
Time / date
Time and date setting
Displays the number of hours remaining until recommended
Hours remaining
maintenance. When "Hi" is displayed, the remaining time exceeds
999 hours.
System information
Displays the current software version
It allows to set the desired temperature for the water supply
Water temperature
(only in con guration 2-5).
Enables or disables Eco Mode, in which the stove automatically
Eco function
switches off and on based on room temperature (only in
con guration 2-5).
Is the number of degrees centigrade below the switch-off
Restart delta
temperature at which the stove switches on again automatically
(except in con guration 1).
Minimum temperature below which the stove switches on
Frost protection temperature
(except in con guration 1).
Lock keypad
Disables the buttons on the keypad
Display brightness
Sets display brightness
Display mode
Sets how the data is displayed
Buzzer volume
Sets the buzzer volume
Combustion
Three different types of combustion can be set
Installer menu
Sets/displays the stove configuration
Manual auger load
Manual activation of the pellet load system
Menu relating to the service centre
Pump power
Menu di competenza del centro di assistenza
Enable/Disable
pump modulation
Menu relating to the service centre
in the Setup menu are password-protected and reserved for service centre personnel.
will be displayed steady
DESCRIPTION
VALUES
1..5
1..5; Auto; Hi
con g.1: 55..
C
con g.2: 1 .. 4
C
con g.3-4: 5 ..75 C
ON - OFF
VALUES
[d1] ... [d7]
[P1] ... [P6]
C
6 ...
OFF; Eco
C
,5 ... 5,
C
... 4
C
OFF; 3 ... 2
C
OFF; 3 ... 5
OFF; Lo; Hi
OFF; 1 ... 5
OFF; 1 ... 4
OFF; 1 ... 5
1 ... 3
PWD: "54"
PWD: "54"
PWD: "54"
PWD: "54"
19