18.If the device is not used for a long time, unplug it from the power source.
19.Always use new batteries to replace the drained batteries in the remote control.
20.Do not move the device when the inner tank is filled with water .
21.Do not place any objects on the device.
22.The device can be used only with properly working ventilation.
23. To provide additional protection, it is advisable to install a residual current device
(RCD) in the electric circuit with a rated residual current not exceeding 30mA. Ask an
electrician for this.
WARNING.
1. It should be remembered that a high level of humidity may favor the development of biological organisms in the environment.
2. Do not get wet the device or wet the area around the device. If moisture appears, reduce the ef ficiency of the humidifying function.
3. Do not allow absorbent materials such as carpets, curtains, tablecloths to get wet.
4. Never leave water in the tank when the device is not in use.
5. During filling and cleaning, disconnect the device from the mains.
6. Clean the device and water tank before using it again.
• WARNING: When the water is not replaced and the tank is not properly cleaned every 3 days, microorganisms that may be present in
the water or in the environment where the device is used or stored may develop in the water tank and be blown out to the surroundings.
This can cause a very serious health risk.
• WARNING: Every three days, empty the water tank and top up with clean water . Before refilling, clean the tank with fresh tap water or
using detergents. Removes any scale, deposits or film that has formed on the sides of the tank and on the interior surfaces. After
washing, wipe all surfaces dry.
DESCALING
1.Perform the descaling procedure in accordance with the instructions of the descaling agent specified by the manufacturer .
2.Use descaling agents intended for this purpose.
3. Carry out the descaling procedure at least every 3 months.
4. Descaling only the water tank with the device turned of

DEVICE DESCRIPTION

1.Cover of top water tank
4. Handle
7. Water inlet with stopper
10. Water tank 12 liters
USING THE APPLIANCE
A noticeable reduction in the temperature of the outlet air occurs after putting into the top water (2) tank one or both plastic containers
(11) attached to the product. Plastic containers (11) should be previously filled with water in ¾ high and frozen in the freezer. It is
recommended to fill the tank (10) with cold tap water.
1. After unpacking the device from the packaging, mount the wheels and set the air cooler on a dry, flat surface, then connect the power
plug.
2. Open the cover of top water tank (1) and pour in the water to water inlet with stopper (7). Be careful not to exceed the maximum level
on water level indicator (6).
3. Turn on the device with the "LOW", "MID" or "HIGH" button on the control panel, thus determining the airflow rate:
"LOW" - slow fan speed
"MID" - medium fan speed
"HIGH" - fast fan speed
4. The "SWING" button causes oscillation of vertical blinds, which ensure even distribution of cooled air streams. The horizontal blinds
do not move automatically - you can move them manually.
5. The "COOL" button reduces the temperature of the exhaust air by activating the water pump. Two plastic containers (11) are included
in the set. To use plastic containers placed them in the freezer for about a day first. Then insert one or both of them into top water tank
(2. The "COOL" function also moisturizes the air.
6. During operation of the device, periodically check the water level for refilling the tank. Do not activate the "COOL" function if the water
level is lower than the minimum level.
7. To end the operation of the device, press the "OFF" button on the control panel.

CLEANING AND MAINTENANCE

It is recommended to clean the device with a soft, dry cloth. Do not use any chemical solvents as they may permanently damage or
deform the surface. If the device will not be used for three months or longer, remove the batteries from the remote control. Pour water
out of the tank before storage by opening the drain plug (8). Dry the device to avoid moisture damage. Set the "COOL" button to the
highest fan speed, the device should work for about 10 minutes to dry the internal filter (5).

TECHNICAL DATA

Supply voltage: 220-240 V ~ 50/60 Hz
Power: 65W
Maximum power: 350W
Capacity: 12L
Water consumption: 1-2 liters / hour
2. Top water tank
3. Bobbin winder bracket
5. Internal filter
6. Water level indicator
8. Drain plug
9. Wheels
11. Two containers for water freezing
To protect your environment: please separate carton boxes and plastic
bags and dispose them in corresponding waste bins. Used appliance
should be delivered to the dedicated collecting points due to hazarsous
components, which may effect the environment. Do not dispose this
appliance in the common waste bin.