954181.book : I95418us.fm Seite 1 Donnerstag, Mai 18, 2000 3:17 PM
Installation
- Finish plaster wall and tile up to the fitting template.
When doing so, seal wall openings against water
splashes.
• In the case of tiles laid in mortar, pointing must be
bevelled outwards.
• In the case of prefabricated walls, seal with elastic
sealing compounds.
- Remove fitting template (A), see fold-out page I fig. [1].
- Unscrew adjusting nut (B). Detach stop ring (C).
- Install stop ring (D), see fig. [2].
- Fit clamp (E).
Mounting escutcheon, see figs. [3] and [4].
1. Install if necessary the compensation ring (G),
see fig. [3].
2. Push sleeve (F) with the mark (F1) upward onto the
mixer shank, make sure that the marking point (F2)
snaps into the sleeve (F).
3. Grease seal (H) with the grease provided, see fig. [4].
4. Slide the escutcheon (J) over the sleeve (F).
5. Slide snap inserts (K) over screws (L) and secure
escutcheon (J) to the valve.
Do not use excessive force to tighten the screws.
6. Cover the srews with cover caps (M).
7. For assembly of the thermostat handle, see chapter
"Adjustment".
If thermostat is installed too deep, the fitting depth can
be increased by 1 1/8" (27.5mm) with extension set Part
No. 47 328, see fold-out page II and III.
Adjustment
Temperature setting, see figs. [5] and [6].
• Before the mixer is put into service, if the mixed water
temperature measured at the point of discharge varies
from the specified temperature set on the thermostat
handle.
• After each service on the thermostat mixer.
1. Open volume control (N) and measure the tempe-rature
of the water emerging with a thermometer, see fig. [5].
2. Turn the green regulator nut (O) clockwise - counter-
clockwise with a screwdriver until the water emerging
has reached a temperature of 100 °F.
3. Fit the thermostat handle (P) so that the 100 °F mark on
the thermostat handle lines up with the mark (F1) on the
sleeve (F), see fig. [6].
4. Insert fixing ring (R) and push decorative sleeve (Q) on
the thermostat handle (P).
5. Push on decorative ring complete (S) and screw on
handle cap (T).
Reversed union (hot on right - cold on left).
Replace thermoelement (47 450) or (47 582), see
replacement parts fold-out page II, ref. No.: 47 282 (1/2")
and 47 379 (3/4").
1
English
Temperature limitation
When in proper calibration, the temperature range is
limited to 110 °F. There is a safety check at 100 °F.
If a higher temperature is desired, one can
exceed 100 °F by overriding the safety check.
Prevention of frost damage
When the domestic water system is drained, the
thermostat mixers must be drained separately, since
check valves are installed in the hot and cold water
connections.
The complete thermostat assembly and check valves
must be unscrewed and removed.
Maintenance
For Maintenance, see figs. [7], [8] and fold-out page II
and III.
Check, clean and if necessary, replace parts.
Grease with special valve grease (Cat. No. 18 012).
Shut off hot and cold water supplies.
I. Thermostat cartridge
1. Turn thermostat handle (47 427) to the 100 °F safety
check, see fold-out page II and III.
2. Remove handle cap (T) and decorative ring
complete (47 429).
3. Take out fixing ring (R).
4. Pull off thermostat handle (P).
5. Pull sleeve (F) from the mixer shank by pressing
down the tongue (U), see fig. [7].
6. Extract clamp (E).
7. Pull stop ring (D) until resistance is encountered
(approximately 3/8" [10mm]), see fig. [8].
8. Unscrew stop ring (D) complete with regulator
nut (O).
9. Remove escutcheon (J), see fig. [4] and installation,
Points 4 - 6, in reverse order.
10.Unscrew thermostat cartridge (47 450, 47 582)
with 24mm (15/16") open-ended wrench, see fold-out
page II and III.
Temperature adjustment is necessary after each service of
the thermostat cartridge (see Adjustment).
II. Check valve
1. Proceed as for maintenance of thermostat cartridge,
points 1 - 4 and 9.
2. Unscrew check valve (14 116, 47 477)
with 17mm (11/16") socket wrench or 3/8" (10mm)
Allen key.
Reassembly should be carried out in reverse order.
Replacement parts, see fold-out page II and III
(* = special accessories).
Care
Instructions for care of this fitting will be found in the
Limited Warranty supplement.