W2000.book Seite 40 Montag, 5. November 2007 6:00 18
Using the battery charger
Disconnecting the battery charger
➤ Plug the power plug (fig. 8 1, page 5) into an earthed and
correctly fused 230 V power socket.
Consult a specialist if you are uncertain.
➤ Connect the red positive terminal of the charger to the positive
terminal of the battery (marked +) (fig. 6 A, page 4).
Note
I
The positive terminal is not connected to the bodywork when it is
connected.
➤ Connect the black negative terminal of the charger to the
negative terminal of the battery (marked –) (fig. 6 B, page 4).
Note
I
The negative terminal is connected to the bodywork when it is
connected.
✓ if the polarity is reversed, the red "Reverse polarity" LED
(fig. 7 1, page 5) lights up. If this happens, swap over the
connections.
✓ The charger is ready to charge the connected battery or provide
a jump start.
6.2
Charging the battery
The charger can charge maintenance-free (gel and fleece) and
non-maintenance-free lead acid batteries (wet) with a rated voltage
of 12 V or 24 V.
Caution – danger of explosions
a
Set the correct charge voltage. Do not use the device on batteries
with other rated voltages.
Note
I
You can interrupt the charging process at any time.
40
All manuals and user guides at all-guides.com
PerfectCharge W2000