AFTER REPLACING A GAS SYSTEM
COMPONENT, CHECK FOR GAS LEAKS AT
CONNECTION POINTS.
DISCONNECT THE APPLIANCE ELECTRIC
SUPPLY, IF PRESENT, BEFORE CARRYING
OUT ANY OPERATION.
AFTER REPLACING AN ELECTRICAL
SYSTEM COMPONENT, CHECK IT IS
CORRECTLY WIRED.
DIRECT HEAT GAS BOILING PAN
GAS VALVE, PILOT, PIEZOELECTRIC DEVICE AND
SPARK PLUG SUBSTITUTION.
- Remove the front panel.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE MAIN BURNER.
- Remove the front panel.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
reverse order.
INDIRECT HEAT GAS BOILING PAN
GAS VALVE, PILOT, PIEZOELECTRIC DEVICE AND
SPARK PLUG SUBSTITUTION.
- Remove the front panel.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE MAIN BURNER.
- Remove the front panel.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
reverse order.
INDIRECT HEAT ELECTRIC BOILING PAN
REPLACING THE KNOB AND INDICATOR LIGHT
- Remove the control panel.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE THERMOSTAT
- Remove the front panel.
Remove and replace the component.
Reassemble all parts. For assembly, proceed in
reverse order.
REPLACING THE HEATING ELEMENT
- Remove the front panel.
- Empty the jacket.
- Remove and replace the component.
- Reassemble all parts. For assembly, proceed in
reverse order.
21. CLEANING THE INTERIOR
Check the condition of the inside of the appliance.
Remove any built-up dirt.
Check and clean the fumes exhaust system.
22. MAIN COMPONENTS
DIRECT HEAT GAS BOILING PAN
- Gas Cock
- Main Burner
- Pilot burner
- Thermocouple
- Igniter
- Piezoelectric ignition
INDIRECT HEAT GAS BOILING PAN
- Gas Cock
- Main Burner
- Pilot burner
- Thermocouple
- Igniter
- Piezoelectric ignition
27