13. Clean the inside of the vacuum chamber of the accessory with compressed air, and if necessary
remove any obstructions.
4
7
6
10

TROUBLESHOOTING

This chapter lists the most common problems linked with the use of the appliance. If you are unable to
resolve the problems with the information given here, please contact your nearest assistance centre.
PROBLEM
POSSIBLE CAUSE
The main switch is not activated.
The plug on the power cable is not
correctly inserted into the electrical
outlet.
The plug on the power cable has not
been correctly inserted into the socket
on the appliance.
The electrical specifications of the
appliance do not match the electrical
specifications of mains supply.
The power cable is damaged.
The vacuum hose is incorrectly
connected to the collection tank.
The vacuum hose is not connected
correctly to the telescopic tube.
The telescopic tube is not correctly
connected to the accessory that is
being used.
The vacuum circuit is blocked
(vacuum hose; telescopic tube;
vacuum accessory).
There is a blockage in the vacuum
filters.
To dispose of the appliance, take it to a demolition centre or an authorised
collection centre.
Before scrapping the machine it is necessary to remove and separate the
following materials and send them to the appropriate collection centres in
accordance with the environmental hygiene regulations currently in force:
Felt
Electric and electronic parts*
Plastic parts
Metallic parts
(*) In particular, to scrap the electric and electronic parts, contact your area
distributor.
10071827-AA_UM_FV9 E.indb 18
2
3
8
9
SOLUTION
Place the main switch on "I".
Connect the power cable plug to the
mains socket.
Connect the plug of the power cable
into the socket on the appliance.
Check that the technical data on the
appliance's rating plate match the
data of the mains supply.
Contact a specialised technician
immediately.
Connect the vacuum hose correctly to
the collection tank.
Connect the vacuum hose correctly to
the telescopic tube.
Connect the accessory correctly to the
telescopic tube.
Remove the obstruction in the
vacuum circuit.
Clear the obstruction in the vacuum
filters.

DISPOSAL

EC DECLARATION OF CONFORMITY

The undersigned manufacturer:
Via Invalidi del Lavoro, 1
37059 Santa Maria di Zevio (VR)
Declares under its sole responsibility that the products
VACUUM CLEANERS mod. FV9 + E
comply with the requirements of the following Directives:
2006/42/CE (+2009/127/CE)
2004/108/CE
2011/65/UE
2009/125/CE
Harmonised rules applied:
EN 55014-1: 2006+A1: 2009+A2: 2011
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 60335-1
EN 60335-2-69
EN 61000-3-2: 2006+A1: 2009+A2: 2009
EN 61000-3-3: 2013
EN 62233: 2008
EN 50581
EN 60312: 2013
Regulations applied:
666/2013
The person authorized to compile the technical file:
Mr. Giancarlo Ruffo
Via Invalidi del Lavoro, 1
37059 Santa Maria di Zevio (VR) - ITALY
Santa Maria di Zevio, 06/06/2017
18
FIMAP S.p.A.
Fimap S.p.A.
Legal representative
Giancarlo Ruffo
13/11/2017 14:30:10

Publicidad

Tabla de contenido
loading

Tabla de contenido