CAUTION: Avoid damaging hydraulic
hose. Avoid sharp bends and kinks when
routing hydraulic hoses. Using a bent or
kinked hose will cause severe back-
pressure. Sharp bends and kinks will internally
damage the hose leading to premature hose failure.
Do not drop heavy objects on hose. A
sharp impact may cause internal damage
to hose wire strands. Applying pressure to
a damaged hose may cause it to rupture.
IMPORTANT:
equipment by the hoses or swivel
couplers. Use the pump lifting/transport
handle or other means of safe transport.
CAUTION: Keep hydraulic equipment
away from flames and heat. Excessive
heat will soften packings and seals,
resulting in fluid leaks. Heat also weakens hose
materials and packings. For optimum performance
do not expose equipment to temperatures of 150° F
[65° C] or higher. Protect hoses and cylinders from
weld spatter.
DANGER: Do not handle pressurized
hoses. Escaping oil under pressure can
penetrate the skin, causing serious injury.
If oil is injected under the skin, see a doctor
immediately.
WARNING: Only use hydraulic cylinders in
a coupled system. Never use a cylinder
with unconnected couplers. If the cylinder
becomes
components can fail catastrophically causing severe
personal injury.

3.0 PRODUCT INFORMATION

Pump
Pump
Max. Pressure Rating
Model
Type
(Speed)
Stage 1
P-18
1
P-39
1
P-77
2
500 [34]
P-80
2
500 [34]
P-801
2
500 [34]
P-84
2
500 [34]
Table 2, Features and Major Components - ULTIMA Series Hand Pumps
Item
(See figures 1 thru 4
for item locations)
A
Release Valve
One 3/8" NPTF
B
C
D
User-Adjustable
E
Relief Valve
F
G
Do
not
lift
hydraulic
extremely
overloaded,
Table 1, Specifications - ULTIMA Series Hand Pumps
psi [bar]
Stage 2
2850 [200]
10,000 [700]
10,000 [700]
1.00 [16.38]
10,000 [700]
1.00 [16.38]
10,000 [700]
1.00 [16.38]
10,000 [700]
1.00 [16.38]
P-18
P-39
Release Valve
One 3/8" NPTF
Outlet Port
Outlet Port
Oil Fill Plug
Oil Fill Plug
Mounting
Mounting
Slots
Slots
User-Adjustable
Relief Valve
cylinder base for added stability. Do not weld or
otherwise modify the cylinder to attach a base or
other support.
addition, the load may slip or fall, causing potentially
dangerous results.
your area. To protect your warranty, use only
ENERPAC oil.
damage. ENERPAC parts are designed to fit properly
and withstand high loads.
damage the hose and/or the pump.
Oil Volume Per Stroke
in
3
[cm
3
]
Stage 1
Stage 2
0.15 [2,46]
0.15 [2,46]
0.15 [2,46]
0.15 [2,46]
0.15 [2,46]
0.15 [2,46]
Pump Model
P-77
Release Valve
One 3/8" NPTF
Outlet Port
Oil Fill Plug
Mounting
Slots
User-Adjustable
User-Adjustable
Relief Valve
3/8" NPTF Return
Bypass Valve
2
WARNING: BE SURE SETUP IS STABLE
BEFORE LIFTING LOAD. Cylinders
should be placed on a flat surface that can
support the load. Where applicable, use a
Avoid situations where loads are not
directly centered on the cylinder plunger.
Off-center loads produce considerable
strain on cylinders and plungers. In
Distribute the load evenly across the
entire saddle surface. Always use a saddle
to protect the plunger.
IMPORTANT: Hydraulic equipment must
only be serviced by a qualified hydraulic
technician. For repair service, contact the
Authorized ENERPAC Service Center in
WARNING: Immediately replace worn or
damaged parts with genuine ENERPAC
parts. Standard grade parts will break
causing personal injury and property
CAUTION: Always use the pump lifting/
transport handle to carry the pump.
Carrying the pump by the hose may
Usable Oil
Weight
Capacity
With Oil
in
3
[cm
3
]
lbs [kg]
22 [360]
11.0 [5,2]
47 [769]
13.6 [6,2]
47 [769]
15.6 [7,1]
134 [2195]
23.6 [10,7]
250 [4095]
31.0 [14,0]
134 [2195]
26.0 [11,7]
P-80
P-801
Release Valve
Release Valve
One 3/8" NPTF
One 3/8" NPTF
Outlet Port
Outlet Port
Oil Fill Plug
Oil Fill Plug
Mounting
Mounting
Slots
Slots
User-Adjustable
Relief Valve
Relief Valve
3/8" NPTF Return
to Tank Port
to Tank Port
Bypass Valve
Bypass Valve
Max. Handle
Effort
lbs [kg]
34 [16]
85 [38]
88 [40]
77 [35]
77 [35]
77 [35]
P-84
4-Way, 3-Position
Control Valve
Two 3/8" NPTF
Outlet Ports
Oil Fill Plug
Mounting
Slots
User-Adjustable
Relief Valve
Bypass Valve