Service Parts - Broan QTRE080C2S Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALL GRILLE
5. Finish ceiling.
Install ceiling material. Cut out around housing.
6. Attach grille to
housing.
Squeeze grille
springs and insert
them into slots on
each side of
housing.
BO0001

SERVICE PARTS

SERVICE NOTE
To remove Blower Assembly:
Unplug motor (6).
Remove screw (4) from motor plate flange.
Find the single TAB on the motor plate (located next to the screw hole).
Push up near motor plate tab while pushing out on side of housing. Or
insert a straight-blade screwdriver into slot in housing (next to tab) and
twist screwdriver.
Key
Part No.
Description
No.
1
97016466
Housing
2
97016449
Duct Connector 4"
3
98010102
Wiring Plate
4
99170245
Screw no. 8-18 x .375"
5
10941351
Wire Panel/Harness Assembly
6
10941352
Blower Assembly (QTRE080C2S)
7
97016497
Grille Assembly (incl. key no. 8)
8
99140199
Grille Spring (2 req'd)
9
99111293
Spacer (2 supplied)
10
97016909
Hanger bars
Order service parts by "Part No." - not by "Key No."
REPLACEMENT PARTS AND REPAIR:
In order to ensure your ventilation unit remains in good working condition,
you must use Broan genuine replacement parts only. Broan genuine
replacement parts are specially designed for each unit and are manufactured
to comply with all the applicable certification standards and maintain a
high standard of safety. Any third party replacement part used may cause
serious damage and drastically reduce the performance level of your unit,
which will result in premature failing. Broan also recommends to contact a
Broan certified service depot for all replacement parts and repair.
7.
Push grille
against ceiling.
10
2
MODEL QTRE080C2S
1
9
3
10
5
6
TAB
8
7
Page 4
9
4

Publicidad

Tabla de contenido
loading

Tabla de contenido