Descargar Imprimir esta página

XPR Access MTPAD- M Manual De Instrucciones página 4

Publicidad

PROGRAMMING FLOWCHART
Change
Master Code
1
Enter New
Master Code
Press 6 Digits
Select Type of Wiegand
2
3
1
2
Wiegand
Wiegand
Wiegand
34bit
26bit
30bit
Direct Menu
exit
Entering Menu is always done with B + 000000 if the Master Code is not changed.
Submenu 1 - Change Master Code. The Master Code must be 6 digits. After enrolling new Master Code the MTPAD-M automatically exits
the Menu and the new master code must be typed to enter the menu.
Submenu 2 - Select Type of Wiegand. With this the Keypad can be adjusted to send 4 different Wiegand Outputs. The Wiegand selected
must be the same as the controller's Wiegand Input where the MTPAD-M Keypad is being connected. Example: If you use a controller that
recognizes Wiegand 34bit, then enter the menu of MTPAD-M, press 2, then press 3.
Submenu 3 - Select Output Protocol. The Keypad can send the Code by different Protocols. Use "Single Wiegand" when connected to third
party controllers. When "Single Wiegand" is selected, what is typed on the Keypad the same will be sent as Wiegand Number. Use Double
Wiegand when connected to EWS, use Clock&Data when connected to controller with Clock&Data input, use Codix when connected to Vi200,
EX5, EX7, INOX99 or VKP99.
Submenu 4 - PIN Code Length. If "0" is selected, then any PIN Code with any length can be sent, but the PIN Code is typed with "A" for
confirmation( ex. 123 + A). If 1 to 8 is selected the PIN Code length is determinated by the number selected.
Submenu 6 - Presets.
The Presets are set of preprogrammed parameters for easy programming.
6-1 "Wiegand 26bit Normal" -
6-2 "Wiegand 34bit Normal" -
6-3 "Wiegand 34bit EWS Mode" -
6-4 "Wiegand 26bit EWS Mode" -
6-5 "Codix" -
Presets 6-3 and 6-4 to be used always when MTPAD-M is connected to EWS firmware ver.2.42 or higher.
Submenu 7 - Site Code Length. S
Submenu 8 - Enter Site Code. Put the site code always in 5 digit format (ex. 00170).
Submenu 9 - Backlight. Turns ON/OFF the backlight.
Enter "Master Code"
1 small beep + 1 long beep + Orange LED is 'ON'
Select Output Protocol
3
1
2
3
4
Single
Double
Clock &
Codix
Data
Wiegand
Wiegand
PIN Code Length
4
0
4
for any length
for lengths
Wiegand
with "A"
40bit
in the end
1 to 8 digits
Type: Wiegand 26bit; Output: Single Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
Type: Wiegand 34bit; Output: Single Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
Type: Wiegand 34bit; Output: Double Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
Type: Wiegand 26bit; Output: Double Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
Output: Codix; PIN Length: any length with "A" in the end; Entry Mode: Card or PIN Code
et the code length sent to Host
B + 000000
No
Validation OK?
Yes
Presets
6
1
2
3
4
5
Wiegand
Wiegand
Wiegand
Wiegand
Codix
26bit
34bit
34bit
26bit
EWS
normal
normal
EWS
Site Code Length
1
1 - 8
Site Code
No Site
between
between
Code
0 to 15
Press "A" to validate
and exit the menu
(orange LED OFF)
. Defaul is "0". To be used only in specific cases.
Error Beep
(3 short beeps)
Enter Site
Code
8
5 digits
7
2
3
4
Site Code
Site Code
between
between
0 to 255
0 to 65535
Backlight
9
0
1
Backlight
Backlight
OFF
ON
4

Publicidad

loading