Note
The installation and management software tools are available from the support pages
on www.axis.com/techsup
To reset the product to the factory default settings:
1. Press and hold the control button and the power button for 15–30 seconds until the
status LED indicator flashes amber. See Hardware Overview on page 9.
2. Release the control button but continue to hold down the power button until the status
LED indicator turns green.
3. Release the power button and assemble the product.
4. The process is now complete. The product has been reset to the factory default settings.
If no DHCP server is available on the network, the default IP address is 192.168.0.90
5. Using the installation and management software tools, assign an IP address, set the
password and access the video stream.
It is also possible to reset parameters to factory default via the web interface. Go to Setup >
System Options > Maintenance and click Default.