Before attaching the air hose, place about 3
cc Oil into the air inlet. This should be done
each day, even when an air line lubricator is
used. During the working day, check the tool
to ensure that the retainer components are
lubricated.
After each two or three hours of operation, if
an air line lubricator is not used, disconnect the
air hose and pour about 3 cc of Oil into the air
inlet of the tool.
If the action of the Scaler becomes sluggish,
pour about 3 cc of a suitable cleaning solution
into the air inlet and run the tool for not more
than thirty seconds.

MAINTENANCE

Immediately after flushing the tool, pour
about 3 cc of Oil into the air inlet and run the
tool for about thirty seconds to lubricate inter-
nal parts.
Before storing a Scaler or if the Scaler is to
be idle for a period exceeding 24 hours, pour
about 3 cc of Oil into the air inlet and operate
the tool for 5 seconds to coat the internal parts
with oil.
Never use a heavy oil or an oil that forms gum.
Either will clog the small parts, restrict valve
motion and cause loss of efficiency. If the op-
eration of the Hammer becomes sluggish, pour
3 cc of a clean, suitable cleaning solution into
the air inlet and operate the tool for 30 sec-
onds. Lubricate in the regular manner immedi-
ately after flushing.
8

TECHNICAL DATA

IMPACTS PER MINUTE
NEEDLE DIAMETER
NEEDLE LENGTH
SCRAPPER
NUMBER OF NEEDLES
AIR CONSUMPTION
AIR PRESSURE
AIR INLET
OVERALL LENGTH
WEIGHT
4 600
3 mm
7" (175 mm)
3"- 3,5" (75 mm - 87 mm)
19 pieces
4 CFM
6,2 BAR / 90 PSI / 620 kPa
1/4" (6 mm)
15" (381 mm)
2,5 kg (5,5 lb)