64 | Help in the event of faults
No.
Designation
(1)
Power
(2)
Sensor
(3)
Transfer
(4)
Fault
BPT-M Touch | Installation manual
For more detailed information on the individual LED
displays, refer to the overview provided on the
following pages.
Meaning of LED indicator
does not light up:
– No supply voltage connected or
– Device has not yet fully started up
does not light up:
– Irradiation and temperature
sensor not connected or not
detected
flashes briefly then goes out:
– Data transfer not successful
lights up:
– A fault in one or more system
components is currently present
flashing:
– An alarm is present which has not
yet been acknowledged
Possible fault rectification
– Connecting the supply voltage
– Wait until the device has fully
started up
– Connect the irradiation and
temperature sensor and restart
BPT-M Touch if necessary or check
the cabling
– Check the cable and Internet
connection
– Restart the BPT-M Touch, if
necessary
– Check the logbook of the system
components
– Rectify the fault (see component
manual)
– Contact the manufacturer's service
centre, if necessary
– Acknowledge the alarm message in
the Overview/Alarm overview
submenu
The alarm message provides
information that an alarm has been
triggered. N.B.: Acknowledging the
alarm message does not rectify the
fault.
– Rectify the fault where possible (see
component manual)
– Contact the manufacturer's service
centre, if necessary