Note:
– You can quit the procedure at any time by simply waiting for 15 seconds, after which
the motor moves 6 times and cancels the procedure.
– After this programming, the s key will move the awning/shutter up and the t key
will move it down. During the Raising manoeuvre, the awning will be stopped by the
impact against the mechanical blocks of the structure (= upper limit switch "0"), while
during the Lowering manoeuvre the awning will stop at the lower limit switch ("1") es-
tabilished by the installer.
5.8 • Programming the position ("H") for par-
tial opening/closing
5.8.1 - To memorize the INTERMEDIATE position ("H")
This procedure does not write the new position over any existing one. The previous posi-
tion must be deleted before proceeding:
01. Position the awning/shutter at the desired height;
02. Hold down keys s and t and wait for the motor to move three times.
5.8.2 - To delete the INTERMEDIATE position ("H")
01. Keep the n key pressed and wait for the motor to perform 2 movements. Now re-
lease the key.
02. Hold down keys s and t and wait for the motor to move 4 times. Then release
the keys.
5.9 • Memorising a SECOND (third, fourth,
etc.) transmitter
To perform this procedure you must have a second transmitter ("old") already memo-
rized.
5.9.1 - Memorising an additional transmitter
01. (on the new transmitter) keep the n key pressed for 8 seconds and then re-
lease it (in this case the motor does not perform any movement);
02. (on the old transmitter) Press any key 3 times to send 3 pulses (it must be a
memorized key, the motor will respond accordingly), such as key n;
03. (on the new transmitter) Press the n key 1 time to complete the procedure.
Caution! – If the motor performs 6 movements, it means that its memory is full.
Note – You can quit the procedure at any time by simply waiting for 15 seconds, after
which the motor moves 6 times and cancels the procedure.
7 – English
5.10 • Functions
5.10.1 - Adjusting the torque reduction level (RDC function)
01. Keep the n key pressed and wait for the motor to perform 2 movements. Now re-
lease the key.
02. Keep the n key pressed and wait for the motor to perform 3 movements. Now re-
lease the key.
03. Hold down keys n + s and wait for the motor to move 4 times. Then release the
key.
a. Hold down key s, activate RDC, and wait for the motor to run 4 movements.
Then release the key.
b. Hold down key t, deactivate RDC, and wait for the motor to run 2 movements.
Then release the key.
Note – You can quit the procedure at any time by simply waiting for 15 seconds, after
which the motor moves 6 times and cancels the procedure.
5.11 • Full delete
5.11.1 - Procedure performed with a memorised transmitter
01. Keep the n key pressed and wait for the motor to perform 2 movements. Now re-
lease the key.
02. Keep the n key pressed and wait for the motor to perform 3 movements. Now re-
lease the key.
03. Keep the n key pressed and wait for the motor to perform 4 movements. Now re-
lease the key.
04. Keep the t key pressed and wait for the motor to perform 5 movements. Then re-
lease the key.
Note – You can quit the procedure at any time by simply waiting for 15 seconds, after
which the motor moves 6 times and cancels the procedure.
5.11.2 - Procedure performed with an unmemorised transmitter
01. Disconnect the power supply from the motor;
02. Connect the power supply to the motor;
03. Keep the n key pressed and wait for the motor to perform 2 movements. Now re-
lease the key;
04. Disconnect the power supply from the motor;
05. Connect the power supply to the motor;
06. Keep the n key pressed and wait for the motor to perform 2 movements. Now re-
lease the key;