The installation must be performed complying the regulations in
force, according to the manufacturer's instructions and by skilled staff .
The manufacturer cannot be held responsible for a wrong installation.
Electrical safety is obtained only when the equipment is connected to
a plug having an effi cient earthing system, equipped with magneto-
thermal diff erential protection, as prescribed by the safety standards in
force.
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR POSSIBLE
DAMAGE CAUSED BY THE ABSENCE OF THE EARTHING SYSTEM OR
NON-COMPLIANCE WITH THE STANDARDS IN FORCE.
Secure the system to a wall that can support the total weight with water
(min. 25 kg). Use the supplied screws fi tting them in the holes on the
sides.
Caution: leave enough space at the front so that the operator can
have space enough for adjustment and/or maintenance operations.

2.1 Installation of cartridges

Before fi tting the cartridge in the vessel make sure that water supply is
closed and there is no pressure, then disassembly the fi lter covers using
the supplied wrench. Position the new cartridge as shown in the picture
and reposition the cover in the proper way, tightening it by the wrench.
Model ROC060 has two inlet fi lters: fi rst position the green charcoal one
(CBEC) and then the white micrometric one (CPP)
2.2 Membrane assembly
Before fi tting the membrane in the vessel
is closed and that there is no pressure. Then move away the pipe from
the connector and, if required, disconnect it from the quick couplings to
create space enough for performing the operation. Undo the vessel cap
and fi t the membrane, paying attention to the fi tting direction (black lip
seal facing downwards). Then, make sure that the membrane is properly
positioned and close the vessel cap.
"osmosi inversa" +0300017IE rel. 1.4 - 05.04.2018

2. INSTALLATION

Fig. 2.a
make sure that water supply

2.3 Water connections

The reverse osmosis system can operate properly when the water supply
pressure ranges between min. 1.5 bar and max. 4 bar.
If pressure is below 1.5 bar, a pressurizing kit must be installed upstream of
the equipment. On the other hand, if pressure exceeds 4 bar, a dedicated
pressure reducer must be installed upstream of the equipment.
2.3.1
Connection of the system supply
Connect the system supply with a pipe having at least the same diameter
as the one of the equipment (1/2" female GAS coupling). Provide for a
cut-off valve upstream of the system.
Provide for a possible by-pass if water is to be supplied to the users even
when the WTS Compact system is stopped.
utenza
users
2.3.2
Connection of the osmotised water line
Connect the pipe of generated water (dia. 6-mm white pipe) to the
couplings of the pressure switches (dia. 6-mm quick coupling).
2.3.3
Connection of the concentrate drain line
Connect the concentrate pipe (dia. 6-mm black pipe) coming from the
fl ow reducer to a free drain (using the dia. 8 black pipe); the connector
between the two pipes D.6 and D.8 is included in the standard supply
(Fig. 2.d, 2.e).
The free drain must be earthed or lower than the same connection. The
supplied connector (3/8" male thread) can be used with the coupling
for a drain pipe, ø 40, from under the sink.