List Of Available Menus - Carel WTS compact Manual Del Usuario

Instalación de ósmosis inversa con bomba
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENG

3.8 List of available menus

1
PROBE CAL. IN
Conductivity probe on feed water
2
PROBE CAL. OUT Conductivity probe on permeate
water
3
OUT SET POINT
Check the conductivity value at the
outlet. If conductivity exceeds the
set threshold (3B) for a certain time
(3D), it locks in DRIVER ALARM FOR
SYSTEM STOPPING
4
IN SET POINT
Check on the conductivity value at
the inlet.
5
LOW LEVEL
Min. pressure switch on permeate
line
6
HIGH LEVEL
Max. pressure switch on permeate
line
7
MINIMUM
Contact of the min. pressure switch
PRESSURE
for feed water
8
MAXIMUM
Check of the value of max. pressure
PRESSURE
downstream of the pump (from
pressure switch calibrated at 12 bar)
9
PUMP TEMP.
Protection of the pump motor from
high temperature
10
FILTER
Forced system stop when the
upstream softener makes salt
regeneration
11
CLEANING
Flushing at the start or after switch-
ing off the system, before or after
each production cycle
WASH CYCLE
Flushing of the membranes in a
cyclical way, every "n" hours and for
a variable "x" duration
12
ALARM
Output of the alarm signal with
connection to an external device
13
RESET
Reset of the counter for the work
hours accumulated by the system
14
SYSTEM TEST
Manual procedure to be activated
individually for each single compo-
nent: to be used during the FIRST
START of the system
15
ALARM TEST
Check if the alarm output is
operating
16
LANGUAGE
Select the display language
17
SET PASSWORD
Entering a new password
18
MAINTENANCE
Maintenance warning interval
19
DOSING PUMP
Locking alarm signal from metering
pump
20
STAND-BY
Input for stand-by (remote on-off )
INPUT
21
PUMP DELAY
Pump delay, recommended when
a return pump is installed upstream
of the system
"osmosi inversa" +0300017IE rel. 1.4 - 05.04.2018
1a
Zero setting of the conductivity probe
1b
Setting of the reading scale of the conductivity probe
2a
Zero setting of the conductivity probe
2b
Setting of the reading scale of the conductivity probe
3a
Enabled / disabled
3b
Conductivity set point at the outlet (from 0.0 to 99.9
μS)
3c
Reading at fl ushing end alarm(locking): enabled /
disabled
3d
Delay time for alarm signal (from 0 min 0 sec to 9 min
59 sec)
4a
Enabled / disabled
5a
Enabled / disabled
5b
State of the high level contact (high pressure): N.C. /
N.O.
5c
Signal acquisition delay (from 0 to 59 sec)
6a
Enabled / disabled
6b
State of the high level contact (high pressure): N.C. /
N.O.
6c
Signal acquisition delay (from 0 to 59 sec)
7a
Enabled / disabled
7b
State of the contact with right pressure: N.C. / N.O.
7c
Signal acquisition delay (from 0 to 59 sec)
7d
Number of attempts before the alarm
7e
Alarm during fl ushing as well: YES/NO
8a
Enabled / disabled
8b
State of the contact with right pressure: N.O. / N.C.
8c
Signal acquisition delay (from 0 to 59 sec)
9a
Enabled / disabled
9b
State of the contact with right temperature: N.C. / N.O.
9c
Signal acquisition delay (from 0 to 59 sec)
10a
Enabled / disabled
10b
State of the contact with active softener: N.C. / N.O.
10c
Signal acquisition delay (from 0 to 59 sec)
11a
Enabled / disabled
11b
Flushing with pump: YES / NO
11c
Flushing with charge solenoid valve open: YES / NO
11d
Flushing at the beginning of production cycle:
enabled / disabled
11e
Duration of the fl ushing from production start
(from 0 to 99 min 59 sec)
11f
Flushing at the end of production cycle:
enabled / disabled
11g
Duration of the fl ushing from production end
(from 0 to 99 min 59 sec)
11h
PERIODIC FLUSHING OF MembraneS: duration of the
fl ushing (from 00 min 00 sec to 99 min 59 sec) and
frequency of the fl ushing (from 00 h to 99 h)
12a
Enabled / disabled
12b
State of the contact with no alarm: N.C. / N.O.
13a
Reset of the hour counter: YES / NO
13b
Reset of the time interval before next maintenance:
YES / NO
UP
Inlet solenoid valve: enabled / disabled
DOWN Discharge solenoid valve: enabled / disabled
RIGHT Flushing solenoid valve: enabled / disabled
LEFT
Pump: enabled / disabled
ENT
Metering pump: enabled / disabled
UP
Press the arrow up to manually activate the alarm
Italian / English / French / German / Spanish
Key in the new password twice to confi rm the choice
18a
Maintenance warning: enabled / disabled
18b
Interval before maintenance warning (from 0 to 19999 h)
19a
Input for metering pump alarm: enabled / disabled
19b
State of the contact with no alarm: N.C. / N.O.
19c
Signal acquisition delay (from 0 to 59 sec)
20a
Remote input: enabled / disabled
20b
State of the contact with no external signal: N.C. / N.O.
20c
Signal acquisition delay (from 0 to 59 sec)
21a
Start delay of the pump for the reverse osmosis system
after opening the charge solenoid valve (from 0 to
999 sec)
14
ROC025 - ROC040
ROC060
not used (due to the ab-
not used (due to the
sence of the conductivity
absence of the conduc-
meter at the inlet)
tivity meter at the inlet)
not used (due to the ab-
already calibrated in the
sence of the conductivity
factory
meter at the outlet)
not used (due to the ab-
enabled
80 μS
sence of the conductivity
meter at the outlet)
disabled
5 min 00 sec
disabled (due to the ab-
disabled (due to the
sence of the conductivity
absence of the conduc-
meter at the inlet)
tivity meter at the inlet)
enabled
enabled
N.C.
N.C.
0 sec
0 sec
enabled
enabled
N.C.
N.C.
0 sec
0 sec
Enabled
Enabled
N.C.
N.C.
05 sec
05 sec
4
4
YES
YES
disabled (due to the
enabled
absence of the max.
pressure switch)
- - -
N.C.
00 sec
00 sec
disabled (due to the
disabled (due to the
absence of temperature
absence of temperature
sensor on pump motor)
sensor on pump motor)
disabled (due to the
disabled (due to the ab-
absence of the upstream
sence of the upstream
softener)
softener)
disabled
enabled
no
yes
yes
yes
disabled
enabled
00 min 00 sec
00 min 20 sec
disabled
enabled
00 min 00 sec
00 min 15 sec
00 min 30 sec every 24 h
01 min 00 sec every
08 h
disabled
disabled
- - -
- - -
absent
absent
absent
absent
absent
Italian
Italian
0077
0077
enabled
enabled
240 h
240 h
not used (there is no
not used (there is no
metering pump)
metering pump)
disabled
disabled
- - -
- - -
- - -
- - -
000 sec
000 sec
Tab. 3.a