1/ INSTALLING YOUR APPLIANCE
Adjust the hob connections: these are
located underneath the control knobs
(Fig. 04) .
— Proceed one tap at a time.
— Remove the control knobs and the gaskets
by pulling upwards.
- Switching
from
butane/propane
-
Using a small flat-head screwdriver, fully
tighten the brass burner power screws
(yellow) (Fig. 05), in a clockwise direction.
-
Replace the gaskets and the control knobs,
noting their direction and ensuring that the
control knobs are fully inserted.
- Switching from butane/propane to natural
gas
-
Unscrew the brass (yellow) burner power
screws (Fig. 05) , using a small flat-head
screwdriver, turn twice anti-clockwise.
-
Replace the control knob.
-
Ignite the burner in maximum heat mode,
then turn down to reduced heat mode.
-
Remove the control knob again, then turn
the burner power screw clockwise until it
reaches the lowest possible setting without
extinguishing the flame.
-
Replace the gasket and control knob.
-
Repeatedly change from the maximum to
the minimum flow rate: the flame must not go
out ; if it does, unscrew the burner adjustment
screw to achieve good flame retention during
these changes.
-
Replace the burner heads, burner covers
and pan supports on the hob.
natural
gas
to
Fig. 04
Burner power
adjustment screw
Fig. 05
13
EN
Control Knob
Tap
Sealing ring
Tap axis

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido