SAFETY INSTRUCTIONS

CAUTION: The equipment contains electrical components under voltage. The equipment may be opened
only by an electrician of appropriate technical qualifi cation. There is a danger of electrical accident!!
(a) The equipment is not intended for use by persons having reduced physical, sensory or mental ability (including children) without being supervised and
instructed by a responsible adult, for use by persons not well acquainted with the operation of the equipment within the scope hereof, persons whose
ability of immediate response is reduced due to consumption of drugs and/or narcotics, etc.
(b) The heat pump shall be located in compliance with the ČSN 33 2000-7-702 standard, i.e. at least 3.5 m from the outer edge of the pool.
(c) The feeding circuit of the heat pump shall meet the requirements of the applicable standard ČSN 33 2000 and shall be provided with the circuit breaker of
the minimum breaking current of 30 mA.
(d) Any intervention into the heat pump electrical installation and the power supply circuit shall be carried out only by an electrician of appropriate technical qualifi cation.
(e) Do not install the heat pump in any place, where it can be fl ooded with water.
(f) Make sure that no children will be present within the heat pump working area. The main switch of heat pump shall not be placed within children's reach.
(g) Do not leave any incomplete heat pump in operation. All its protecting covers shall be always installed! The rotating blower may cause a serious body
injury. If in operation, the inner piping is hot and may cause burns.
(h) If it is found that the extension cable or supply cable of the pump is damaged, immediately switch the power supply circuit breaker OFF and have the defect made right.
(i) Any repairs of the heat pump and intervention in its pressure circuit of coolant shall be performed only by a duly qualifi ed specialist.
(j) Maintenance and operation of this equipment shall be carried out in due compliance with these Instructions and their recommended frequency and periods shall be observed.
(k) Only original spare parts shall be used. Any failure to observe these recommendations may cause the guarantee provided with this product shall become
void and any claims will be refused accordingly.
3.0

EQUIPMENT DESCRIPTION AND TECHNICAL SPECIFICATION

3.1

TECHNICAL DATA

TYPE
Power supply
Protection degree
Protection class
Heating capacity*
Cooling capacity*
Rated power input*
Operational power input*
Rated current *
COP (heating, operational)*
Required water fl ow rate (min)
Air fl ow rate
Noise level
Coolant (heat transfer fl uid)
Cooling gas charge weight
Equipment weight
Dimensions (L x D x H)
* These values may vary subject to climatic and operating conditions.
3.2

POOL WATER PARAMETERS

The heat pump is designed for heating pool water that meets the requirements for its harmlessness in terms of bathing. The limit values for heat pump
operation: pH within the range of 6,8 – 7,9, chlorine total content shall not exceed 3 mg per litre. Water hardness shall be kept at the lower limit of its
optimum range, i.e. slightly above 8 °dGh.
4
BP-85HS-A
(V~ / Hz)
230 / 50
IP X4
I
(kW)
8,5
(kW)
6,8
(kW)
1,7
(kW)
1,6
(A)
7,9
5,0
³
(m
/h)
4,0
³
(m
/h)
2000
(dB(A))
<52
R 410A
(g)
950
(kg)
52
(cm)
93 x 28 x 55
BP-100HS-A
BP-120HS-A
230 / 50
230 / 50
IP X4
IP X4
I
I
10,5
12
7,8
8,3
2,05
2,35
1,9
2,25
9,0
11,0
5,1
5,3
4,5
6,0
2400
2800
<53
<54
R 410A
R 410A
1100
1300
61
63
101 x 31 x 61
101 x 31 x 66
BP-140HS-A
230 / 50
IP X4
I
14
9,6
2,7
2,6
12,5
5,4
7,0
3200
<55
R 410A
1500
68
107 x 34 x 70