Water Supply

The integrated water swivel works directly through
the motor shaft to provide continuous cooling of the
core bit in wet drilling applications.

Electrical Safety

The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
WALT tool is double insulated in
E
accordance with EN 60745; therefore no
earth wire is required.
If the supply cord is damaged, it must be replaced
by a specially prepared cord available through the
D
WALT service organization.
E
Using an Extension Cable
If an extension cable is required, use an approved
3–core extension cable suitable for the power
input of this tool (see technical data).The minimum
conductor size is 1.5 mm
2
; the maximum length is
30 m.
When using a cable reel, always unwind the cable
completely.
Mains Plug Replacement
(U.K. & Ireland Only)
If a new mains plug needs to be fitted:
• Safely dispose of the old plug.
• Connect the brown lead to the live terminal in
the plug.
• Connect the blue lead to the neutral terminal.
Follow the fitting instructions supplied with good
quality plugs. Recommended fuse: 13 A.
Fitting a Mains Plug to 115 V Units
(U.K. & Ireland only)
• The plug should be fitted by a competent
person. If you are in doubt, contact an
authorized D
WALT repair agent or a qualified
E
electrician.
The plug fitted should comply with BS EN 60309
(BS4343), 16 Amps, earthing contact position 4th.
DI-switch (in-line protector PRCD)
(fi g. 1)
The machine is equipped with a portable residual
current device (PRCD) (i), which protects the user
against electric shock by interrupting the circuit
when a leakage current of 10 mA or greater is
detected. For 115 V units the rated leakage current
is 6 mA.
34
WARNING: Never operate the machine
without the PRCD in place. Do not
use the machine if the PRCD does not
function properly. For the PRCD to work,
the machine must be connected to an
earthed wall socket.
TO SWITCH ON THE RCD
I = ON (red LED lights up).
Switch on the machine (also refer to the section
Switching On and Off).
To switch off, proceed in reverse order.
TO TEST THE RCD
O = Test button: the switch must break the circuit
(machine switches off).
WARNING:
• If in the test mode the switch does not
break the circuit, we recommend that
the unit is inspected by an authorized
D
WALT repair agent.
E
• It is not permitted to make any
modifications to the machine, in
particular it is not allowed to open
the PRCD or to repair or replace the
cable.
• Never use the PRCD as a main
switch. Always switch the PRCD
under no load condition.

ASSEMBLY AND ADJUSTMENTS

WARNING: To reduce the risk of
injury, turn unit off and disconnect
machine from power source before
installing and removing accessories,
before adjusting or changing set-
ups or when making repairs. Be sure
the trigger switch is in the OFF position.
An accidental start-up can cause injury.
Fitting the Side Handle (fi g. 3)
The side handle (e) can be fitted to suit both
RH- and LH-users.
WARNING: Always use the tool with
the side handle properly assembled.
1. Twist the side handle to loosen it.
2. For RH-users, slide the side handle clamp over
the collar, handle at the left.
For LH-users, slide the side handle clamp over
the collar, handle at the right.
3. Rotate the side handle to the desired position
and tighten the handle.