• The electrical, height adjustable underframe must only be assembled with one of the following
table tops – model nos . 80702, 80703, 80706, 80707 or 80708 .
• The maximum evenly distributed load on the table top is maximum 50 kg., including everything on
the table .

4 CONNECTING THE TaBLE

• The electrical height adjustable table must be connected to 220-240 VAC/50 HZ.

5 WaRNINGS

 The packaging must be kept out of reach of children due to the danger of suffocation .
 Beware of the danger of pinching if, for instance, the table is placed too close to window sills,
drawers or other furniture . Keep a distance of minimum 3 cm . between the edge of table and the
item and 40 cm between the underside of the table and the item .
 The height adjustment must only be carried out by an adult because of the danger of suffocation
or injuries .
 Do not alter or rebuild the table . Do not under any circumstances interfere with the electrical
system .
 The table must not be sued to lift persons or similar .
 The table must only be used for the assigned purpose – ordinary private office use, with an evenly
distributed load on the table top of 50 kg .
 The table must only be used in an ordinary indoor climate and is unsuitable for bathrooms or
similar damp places .
 Please be careful of other persons, including children, moving around the table when adjusting
the height .
 If the table is left unattended where children are present, pull out the plug from the socket .
 If you need to move the table after assembly and installation, pull out the plug and then
disassemble the table top . Do NOT lift the table by the table top .
 The switches for adjusting the height must be placed at a distance of minimum 130 cm . in order to
prevent a child from adjusting the height accidentally .

6 TECHNICaL SPECIFICaTIONS

Weight of underframe:
Width:
Depth:
Height adjustment:
Speed:
Operation:
Maximum evenly distributed load:
Electrical switch:
Consumption:
Standby consumption:
Operation temperature:
Operation air humidity:
Storage temperature:
Storage air humidity:
58
32 kg
1600 mm (without table top)
800 mm (without table top)
68 – 120 cm .
~25 mm/sec
Tumbler
50 kg
220-230 VAC/50 HZ
80 W
0,75 W
10ºC to 40ºC
<80% relative air humidity
0ºC to 40ºC
<90% relative air humidity