1 Insert tungsten electrode with the blunt end into the back cap about 5mm
deep.
2 Slide both parts into the torch body and screw them down with the back
cap.
3 Unscrew screwed-in back cap half a turn counter clockwise.
4 Slide centering ceramics from below into torch body.
5 Screw alignment gauge onto torch body as far as it will go. This pushes the
tungsten electrode back to the preset setting dimension.
NOTE
• The standard setting dimension for the electrode setting is 3 mm.
6 Tighten back cap. Tungsten electrode is clamped.
7 Unscrew alignment gauge.
8 Insert insulating ring, screw in distributor ring and gas diffuser.
9 Insert plasma nozzle and tighten it by means of the fastening nut.
10Push the gas diffuser back against the fastening nut and tighten it.
11 Screw down gas nozzle.
NOTE
To dismount the distributor ring, a separate tool is available.
• Order data and ID numbers can be found in the current order
documents.
 see 4 Scope of delivery on page EN-7
6 Putting into operation