3. STARTING-UP

Turn the unit on through the on/off switch on the
back panel.
The unit will perform a general system check
then will show the first screen.
PR
4%
Soft
Cycle
Torque
ScrOK
ScrNOK
CycleOK
2
1
Legend
1
Knob encoder
2
Mains screen
Push MENU button for 1 second and display the
main screen (2) indicating the Program (1 to 8),
the Torque Level, the Joint type (Hard or Soft),
the Screws Done and Set and the Rejected
Screws.
The five upper fields indicate the setting of the
unit:
PR_ cycle
program set, from 1 to 8 or EXT.
% Torque
programmed torque as a
percentage
Soft/Hard
programmed joint.
Joint
Screws
screws done on a batch.
Done/Set
Reject
number of rejected screws.
The five lower fields represent:
ScrOK
Correct tightening done
between min and max time.
ScrNOK
Incorrect tightening done under
min time or over max time.
CycleOK
Cycle OK and not exceeding the
programmed reject screws.
CycleNOK
Incorrect cycle, one or more
screws have been rejected , or
cycle time have been overtaken.
END
End of a cycle or of a sequence.
8 / 296
SCREWS
OVER
0/5
1/1
Joint
Done/Set
Reject
CycleNOK
END

4. MENU

To enter the password and to move through the
menu, use the knob on the front panel of the
unit:
● To move through the fields, just turn it.
● To enter a field and modify the value it must
be pushed and turned until you reach the
desired value.
● To save the value, push it again.
● To go back push ESC and to go out push
ESC again.
Values are saved automatically moving
through a screen to another or returning
to the first screen.

5. PROGRAMMING THE UNIT

To enter the programmable menu push the
MENU button for 5 seconds.
At the first startup (and every time after the unit
has been switched off) the unit will ask for a
password.
5.1. Enter / modify Password and
Language
1
PASSWORD:
ENTER ESCAPE CHANGE PWD
Legend
1
Password screen
2
Language selection
● Push the MENU button for 5 secs.
● Push the knob and enter the four digits of the
password (default password is: 1111).
Once entered the password, turn the encoder to
ENTER, push it and the unit will show the first
screen.
To modify the password:
● Enter the old password.
● Select CHANGE PWD.
● Enter the new one and save it pushing the
encoder.
Once entered, to move through the 4
programming screens just push the MENU
button.
2
_ _ _ _
LANGUAGE
ENGLISH
05/2020