Walk Test
NOTE:
To perform the walk test, first enable the LEDs.
Two minutes after applying power (warm-up period), walk test the detector over the entire protected area
to verify proper operation of the detector and observe the Tri - color LED. The edge of the microwave
pattern is determined by the first red LED activation (both PIR and MW LEDs are triggered).
NOTE:
If the PIR/MW LEDs do not TURN ON, probably it means that there
is a problem with either the lens (PIR) position, or MW adjustment!
Adjust the microwave sensitivity by turning the PCB potentiometer (using a screwdriver), or by using the
Remote Control device. Walk test the unit from all directions to determine all the detection pattern
boundaries.
NOTE:
Adjust the MW to the lowest possible setting that will still
provide enough coverage for the entire protected area!