Routine maintenance

Periodic and correct maintenance of the vacuum pump
will ensure a long operation life and constant
performance.
Lubrication
The oil provided with the pump has been specially
formulated & manufactured to lubricate vacuum pumps;
it is special as it features minimum viscosity fluctuation
when in use under a wide temperature range. The type of
lubricant supplied with the pump allows the evacuation of
systems operating with CFC, HCFC and HFC refrigerants.
Working with ROTHENBERGER POE synthetic oil is also
feasible.
Both ROTHENBERGER oil types available after order.
Volumes to be filled into the pumps are specified in
section 1.1. Replace the initial oil charge no later than 150-
200 hours of operation; further replacements should be
carried out every 600 hours of correct usage.
Oil could be polluted by other oil, humidity, refrigerants,
etc. It is mandatory to use oil in perfect conditions to
assure a perfect performance of the pump.
Oil-change
Over-used
lubrication
mechanism; make sure to replace oil as soon as it starts to
turn cloudy. For conducting the oil-change, the pump
must be switched off. For changing the oil proceed as
follows:
Problem Solution
The pump doesn't work
Overheating
INSTRUCTIONS FOR USE
oil
damages
the
1. Check that the pump is connected to the power supply.
2. Check that the plug and cable are not damaged.
3. Check that the power supply is suitable for the pump requirements ( see the
label of the pump ).
4. Check that the pump is filled up with oil (see section 2.1).
5. Contact our Service-After-Sales.
1. Check that the pump is filled up with oil (see section 2.1).
2. Check that the pump is bot covered and that air could flow easily.
3. Check that the power supply is suitable for the pump requirements ( see the
label of the pump ).
4. Contact our Service-After-Sales.
1. Unscrew the oil drainage plug located on the lower
part of the pump
2. Check that oil comes out completely from the pump
3. Tightly screw the oil drainage plug back on
4. Re-fill the pump with oil (see "Filling of oil")
WARNING: Do not pollute the environment by spilling
oil; the lubricant oil is a special waste and must be
disposed of according to relevant local law / guidelines
in force.

Extraordinary maintenance / repair

Conduct extraordinary maintenance or repair whenever
serious faults occur such as overheating, poor ultimate
vacuum, persistent loudness / noise, blocked pump or any
other irregular functioning. In that case, the pump needs
to be disassembled, parts need to be cleaned, repaired or
replaced. Only qualified service staff shall carry out such
maintenance or repair work; otherwise the warranty will
be void. For any information please contact our Service-
After-Sales.
pumps'
ENGLISH
16
Problem and Solution