Model #HTR-REV02-L
www.homewerksww.com
All manuals and user guides at all-guides.com
Instructions
5-1. Insert the suspension bracket into the bracket cover of duct side and the back
of the fan body. The brackets adjust to the distance between the joists.
5-2. Insert the fan between joists. Make sure the fan body is level and perpendicular
with the joist, and flush with ceiling surface.
5-3. Allow for thickness of the ceiling board used in your application. DO NOT FLUSH
MOUNT TO JOIST. Fan body should be flush with ceiling board.
5-4. Secure the suspension bracket to joists by using long wood screws.
5-5. Secure the suspension bracket to fan body by short machine screws.
6.
Duct connection.
CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES.
6.1. Snap the damper/duct connector onto housing. Make
sure that tabs on the connector lock into housing slots.
6-2. Insert the duct into the duct connector and tape all
duct work connections to make them secure and air
tight.
6-3. Do not install the unit where ducts are configured as
shown in Fig. 3.
6-4. Install the duct with a gradient 1°~2° to the outside.
7.
Complete the installation.
7.1 Refer to Fig. 4, insert the plug from the heating
unit into the receptacle marked "HEAT", and the
plug from the fan into the receptacle marked
"VENT", and the plug from the light into the
receptacle marked "LIGHT".
7-2. Install light reflector into grille by using one medium
machine screw as shown in Fig. 5.
WARNING: DO NOT USE LONG WOOD SCREW IN PLACE
OF MEDIUM MACHINE SCREW.
Medium
machine
Long wood
screw
screw
CAUTION: Install a light bulb 60 watt maximum
(not included).
To save energy use compact flourescent bulbs.
7-3. Install light lens into grille/reflector assembly.
Item# 398999
Ventilation Fan
Light
Heater
Fig. 5
Effective/Rev. date: March 15, 2012
7