Quickguide SPG-DIGI
This is a quick guide with the safety and basic function information.
The full manual can be downloaded at www.stauff.com/spg-digi/manuals
Introduction
The SPG-DIGI is a digital manometer featuring a MIN/MAX display function. Full scale (FS) accuracy is ± 0,5% based on
the upper limit of the measurement range. Dynamic pressure peaks are measured at a scanning rate of 10ms
(100 measurement values/second). The MIN/MAX memory is continuously updated and rewritten.
Safety information
Before you work with the sensor, read and heed the information in these quick guide. Failure to follow the instructions
provided, especially the safety information, can pose a danger to humans, the environment, and other
equipment. The sensor represents the state of the art in terms of accuracy, operating principle as well as safe and
reliable operation.
Comply with existing national regulations for accident prevention and safety at the workplace when working!
Note the IP protection rating when using the sensor in moist areas
Allow only trained technical personnel to install the sensor!
Comply with the specified tightening torques!
Do not apply any force to the sensor!
Incorrect mounting of the manometer and the corresponding adapter can cause the manometer
to be torn out of the assembly.
Please do not assemble while the SPG-DIGI is pressurized
Safety instructions for using the 1.000 bar operating range:
Please note that special connection adapters are available which are approved for a nominal working pressure
of 1.000 bar. Please pay attention to build in test points acc. to rated nominal pressure
and specified safety factors.
Never use a damaged or defective sensor!
Intended use
The sensor has been designed for measurement of pressure in the approved ranges below.
Any other application beyond the above use of the sensor is prohibited, can result in accidents or destruction of the
sensor and immediately voids any and all warranty claims against the manufacturer.
Misuse
The sensor does not comply with Directive 2014/34/EU and for this reason may not be used in potentially explosive
atmospheres.
Technical personnel
These operating instructions are intended for trained technical personnel who are familiar with the applicable regulations
and standards in the field of application. The technical personnel entrusted with commissioning and operating the device
must have suitable qualifications. The qualifications can be acquired in the form of training or appropriate instruction.
The technical personnel must be familiar with the content of these operating instructions, which must always be
accessible.
For Service, Repair and Calibration of the measurement instruments please contact your STAUFF sales branch.
Installation
Connection to the Hydraulics
The SPG-DIGI is available with male thread G 1/4 (BSPP) or 7/16-UNF for the corresponding versions (bar / psi).
Several adapters for other pressure connections can be supplied also.
Please make sure that the device is properly mounted to avoid malfunctions.
Please do not assemble while the SPG-DIGI is pressurized.
Observe specified torques when fitting the SPG-DIGI (1/4 BSPP 25 Nm; 7/16-20 UNF 35 Nm)
Display and Functions
• 4 1/2 digit LCD with backlight
• Displays measurement values and menu functions
• „Bar-graph" with peak & hold function
• Actual Value display (size 15mm)
• MIN/MAX or Full Scale (FS) (8 mm)
• Battery status
Key
Function
ON/Off:
Switches the device on / off.
Light:
Press 2s. Turns the backlight on (stays on for 20 s)
MIN/MAX/FS:
Select display value: MIN, MAX or FS
(Clock:)
(Press 2s. Time setting menu) Only with SPG-DIGI-USB
ZERO:
Zero calibration
MENU:
Press 2s. Setting menu is displayed
RESET/OK:
Clears MIN and MAX values from memory. Confirms the menu functions.
(Rec:)
(Starts and stops the measurement) Only with SPG-DIGI-USB
Maximum Values
Range
Display
Display
bar
PSI
mbar
-1...5
-14,5...720
-0,999...5000
-1...16
-14,5...230
-0,999...16000
0...100
0...1450
-
0...400
0...5800
-
0...600
0...8700
-
0...1000
0...14500
-
Range (bar)
-1...5
-1...16
0...100
Overload Pmax (bar)
30
32
200
Burst Pressure (bar)
50
160
800
Range (PSI)
-14,5...72,52 -14,5...230
0...1450
Overload Pmax (PSI)
435
464
2900
Burst Pressure (PSI)
725
2320
11603
Exceeding the maximum overload values (Pmax) can lead to malfunctions and result in the
SPG-DIGI being destroyed.
Protection class
IP Class 65
Maintenance
The sensor is maintenance-free and cannot be repaired by the user.
In the event of a defect, the sensor must be returned to the manufacturer for repair.
Cleaning
Use a dry or lightly moistened, lint-free cloth to clean the outer surfaces of the sensor.
NOTE
Risk of material damage from aggressive and chemically etching substances.
Never use abrasive or volatile cleaners!
Do not use sharp objects or aggressive cleaners!
Conformity
The SPG-DIGI meets the guidelines of the European Community (EU). 2014/30/EU and 2011/65/EU
It is confirmed that this product is approved acc. to following standards:
DIN EN 61326-1:2013-07
EN 50581:2012
Display
Display
kPa
MPa
-100...500
-0,1...0,5
-100...1600
-0,1...0
0...10000
0...10
0...4000 (x10)
0...40
0...6000 (x10)
0...60
0
0...100
0...400
0...600
0...1000
800
1000
1000
1700
2000
2000
0...5800
0...8700
14500
11603
14504
14504
24656
29008
29008

Publicidad