7.
Screw in a new phosphate cartridge in clockwise
direction into the sludge and air separator
– Tighten not too tightly
8.
Open the stop valve ahead of the sludge and air
separator to rinse out any possible foreign particles
through the lower ball valve
9.
Close the lower ball valve again
10.
Slowly open the stop valve following the sludge and
air separator
11.
Put the heater system back into operation
12.
Refill heater system if necessary
6.2.4 Cleaning the magnetic separator
The integrated magnetic separator serves to reliably separate
ferromagnetic metals in the heater system. The blind plug
included in the scope of delivery contains the magnetic
separator.
Due to corrosion reasons, the magnetic separator
should be cleaned regularly.
1.
Put the heater system out of operation
2.
Close the stop valves ahead and following the sludge
and air separator
3.
Place a suitable, heat-resistant container underneath
4.
Release the pressure in the sludge and air separator
by opening the lower ball valve
5.
Screw out the blind plug (SW27)
– If the phosphate cartridge is installed, take off the
filter basket
6.
Clean the magnetic separator integrated in the blind
plug from all collected particles
CAUTION!
Do not use any chemical cleaners.
7.
Screw the blind plug in with not too much force
8.
Open the stop valve ahead of the sludge and air
separator and rinse out the filter to clean out any
foreign particles through the lower ball valve
9.
Close the lower ball valve again
10.
Slowly open the stop valve following the sludge and
air separator
11.
Put the heater system back into operation
12.
Refill heater system if necessary
MU1H-1549GE23 R0420
GB
7
Disposal
Observe the local requirements regarding correct waste
recycling/disposal!
8
Spare Parts
For Spare Parts visit homecomfort.resideo.com/europe
9
Accessories
For Accessories visit homecomfort.resideo.com/europe