INSTRUCTIONS FOR USE
Battery installation and charge
9.
Install the batteries on the machine according to the
diagram (10, Fig. J).
10. Charge the batteries (see the procedure in the
Maintenance chapter).
NOTE
The machine does not operate if the battery
charger is not connected to the batteries.

DECK INSTALLATION/REPLACEMENT

On 20DC and 20DD versions it can be installed both the
brush/pad-holder deck (9, Fig. C) and cylindrical brushes
deck (32).
See chapter Maintenance, for installation/replacement.
Brush or pad-holder installation/replacement
1.
On the machine with the related deck installed (9, Fig.
G) it can be installed the brush (16, Fig. J) or the
pad-holder (17) with the pad (18) according to the
floor type.
2.
Lift the brush/pad-holder deck (9, Fig. C) with the pedal
(20).
3.
Position the brush/pad-holder (16/17, Fig. J) under the
brush/pad-holder deck.
4.
Lower the brush/pad-holder deck (9, Fig. C) with the
pedal (20).
5.
Press the brush switch (5, Fig. B) for a few seconds to
engage the brush/pad-holder.
Cylindrical brushes installation
6.
Lift the cylindrical brushes deck (32, Fig. C) with the
pedal (20).
7.
Turn the ignition key (9, Fig. B) to "0" position and
remove the key.
8.
Remove the handwheels (28, Fig. J) and the doors (27)
pushing them down and pressing the handwheel.
9.
Install the cylindrical brushes (26, Fig. J).
Cylindrical brushes can be installed from both sides.
10. Reinstall the doors (27, Fig. J) and lock them with the
handwheels (28).
Squeegee installation
11. Install the squeegee (10, Fig. C) and fix the knobs (11),
then connect the hose (26) to the squeegee.
12. Using the knob (12, Fig. C), adjust the squeegee so that
its rear blade (14) (in all its length) touches the floor and
that the front blade (13) is slightly detached from the
floor.
8
Adjustments
13. Using the handles (3), adjust the handlebar (2, Fig. C) to
reach a comfortable position.
Solution tank filling up
14. Open the tank cover (1, Fig. G).
15. Fill the solution tank (5, Fig. G) with an appropriate
solution for the cleaning to be carried out.
It is possible to check the solution level in the tank with
the marks (27, Fig. C).
Do not fill the solution tank completely and let the
solution level a few centimeters from the rim.
Always follow the dilution instructions on the label of the
chemical product used to create the solution.
The solution temperature must be under 100°F (40°C).
CAUTION!
Use only low-foam and non-flammable
solutions, appropriate for the machine.

STARTING AND STOPPING THE MACHINE

Starting the machine
1.
Prepare the machine as described in the previous
paragraph.
2.
Lower the squeegee (10, Fig. C) with the lever (19).
3.
Lower the brush (8, Fig. C) with the pedal (20).
4.
Position the solution flow control lever (7, Fig. B) in the
most appropriate position, depending on the type of
cleaning to be carried out.
5.
Keeping a hand on the handlebar (2, Fig. C), start the
machine with the brush and suction switches (5 and 6,
Fig. B).
NOTE
If the green warning light (2, Fig. B) turns on,
the machine is ready to be used. If the yellow
or red warning light (3 or 4, Fig. B) turns on,
charge the batteries before starting cleaning
(see the procedure in the Maintenance
chapter).
Stopping the machine
6.
Turn the brush and suction switches (5 and 6, Fig. B) to
"0".
7.
Lift the brush with the pedal (20, Fig. C).
8.
Lift the squeegee with the lever (19, Fig. C).
9.
(20DD versions only): Turn the key (9, Fig. B) to "0".
Micromax™ 17B–20B / 20DC–20DD — 909 5426 000(2)2005-03