and ended 10 May 2013 at midnight).
- rESEt : press and hold more than 3 seconds on OK to reset the appli-
ance's power and reset the consumption counters.
- P1500 : the appliance's declared power (for example: P1500 for 1500W).
If you make a mistake, reset to zero (rESEt).
MENU 2
MENU2 access the following secondary functions :
SETTING THE TEMPERATURE OFFSET
This setting compensates for any difference between the temperature dis-
played by the heater and ambient temperature measured in the room.
This difference varies from one room to another as it depends on the insu-
lation, room layout and location of the heater.
This difference must be closed when the ambient temperature is stabilised
after more than 2 hours of heating without changing mode.
This setting changes neither the stability nor the accuracy of the tempera-
ture regulation.
- Press MENU to access the menus.
- Press ► to select MENU2.
- Press OK to access the secondary menus ;
the OFFSt menu is displayed.
- Press OK to enter this menu.
- Press + or – to set the offset between 8°C
and -8°C.
- Press OK to validate the offset.
- Press MENU to exit the menus.
For example, if the heater is set at 20°C and if the ambient thermometer
displays 18°C, the offset must be -2°C.
For example, if the heater is set at 20°C and if the ambient thermometer
displays 22°C, the offset must be 2°C.
13