Fresh water line
The fresh water line runs from the fresh wa-
ter distributor to the float valve.
Installing the attachment set for emergency frost protection (optional)
X1
System separator
X2
Fresh water
Y1
Filter fixture - frost protection
Y2
Processed water, external frost pro-
tection shaft
-NOTICE
The attachment set for emergency frost
protection should always be connected in
the area of the fresh water inlet (building
side) so that there is adequate water supply
even if the supply pressure is low.
Turn out the stopper R 1 1/4" from the
T-piece of the system separator (op-
tional).
Cut the filter fixture for frost protection
according to the reduction sleeve 1" - 1/
2".
Screw and install the parts according to
the drawing after using sealing tape.
WARNING
Follow the prescribed flow direction of the
locking valves, pipe ventilators and back-
flow valves.
Unscrew plugs from T-piece on the 3-
way fresh water distributor.
For SB MU fresh water supply, choose
according to structural conditions.
Scope of delivery
Item: Description
110
Reduction sleeve 1 1/4" - 1/
2"
111
Double nipple 1/2"
112
Sleeve valve 1/2"
113
Pipe ventilator 1/2"
114
Sleeve 1/2"
115
Hose nipple 1/2"
116
Hose clip 1/2"
117
HOSE 1/2"
118
Solenoid valve 1/2"
Assembly instructions
3
-
EN
Attach the double nipple, valve and
hose nipple as shown above.
Cut the hose to the required length.
Connect valve and float valve as shown
opposite.
119
T-piece 1/2"
Piece
120
Backflow valve 1/2"
1
--
Sealing tape
1
2
1
1
1
1
1
2
1
1
1
9