battery connector and pressing in while turning clockwise one quarter turn. Refer to Figure 3-6 for
the location of the connector.
3.2.4.
Disconnecting from the Battery Pack
To disconnect the battery from the battery cable for charging, twist the cable connector on the end of
the cable counterclockwise one quarter turn while pulling out gently. After the cable has been
removed, the battery may be transported to a safe area where it can be charged.
64062816
|
09
|
05/2021
Note that the 64050625/30538111 battery packs are shipped from the factory without a full
charge. Before use, the battery pack must be placed on the charger in the safe area and
charged for at least 11 hours.
Figure 3-6 shows the connection for the 64050625 battery pack. The 30538111 model is
similar.
METTLER TOLEDO NiMH Battery Pack Installation/Technical Manual
Figure 3-6: Connecting the Battery
Figure 3-7: Disconnecting the Battery