DAMAGE
1
2
No flow of water
from tap
The water flows for
1 minute (without any
object in front of sensor)
finally stop
min
1
s
The water remains open
over 1 min
min
>1
s
The faucet opens /
closes independently
with no reason
1
Water betwwen handle
and body
It flows only hot
or cold water
Out-let flow reduced
Non-appropriate
temperature
regulation
Only hot or cold
water flows,regardless
of the handle selected
CAUSES
OFF
Exhausted battery (the led blinks)
Electrical problem
Filter is dirty
Blocked solenoid valve
Dirty sensor
Light reflections on the sensor
Electrical problem
Blocked solenoid valve /
damage sensor
It's been 24 hours since the last one Correct operation
supply
Light reflections on the sensor
- Cartridge blocked
Blocked solenoid valve
- Insufficient working pressure
- Cartridge blocked or dirty
- Outlet obstructed by dirt or
limestone
- Filters in-lets obstructed by dirt and - Disassemble and clean filtres
limestone
- Cartridge blocked or dirty
- Hot water temperature insufficient
Water in-lets inverted
SOLUTIONS
ON
Replace the battery
- Disconnect and reconnect the battery
- Check the connections and
the cable's integrity
- Damaged sensor: ask for
Clean the sensor window
Ask for
Clean the sensor window
- Remove the reflection sources
- Adjust the servey distance
Disconnect and reconnect the battery
(RESET)
Ask for
- Remove the reflection sources
- Adjust the servey distance
- Replace cartridge
Ask for
- Pressure check
- Replace cartridge
- Disassemble and clean aerator
- Replace cartridge
- Check the system
Invert water in-lets